UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Inhibition of Defocus-Induced Myopia in Chickens

Loading...
Thumbnail Image

Date

2013-04-12

Authors

Woods, Jill
Guthrie, Sarah E.
Keir, Nancy
Dillehay, Sally
Tyson, Mark
Griffin, Richard
Choh, Vivian Cheng-Pei
Fonn, Desmond
Jones, Lyndon W.
Irving, Elizabeth

Journal Title

Journal ISSN

Volume Title

Publisher

Association for Research in Vision and Ophthalmology

Abstract

Purpose.: To determine the effect of wearing a lens with a unique peripheral optical design on the development and progression of defocus-induced myopia in newly hatched chickens.Methods.: Eighty-five newly hatched chickens underwent bilateral retinoscopy and A-scan ultrasound to determine their refractive error and axial length. They were randomly divided into Control and two Test groups, in which each chicken was fitted with a goggle-lens over the right eye, with the left eye remaining untreated. The Control group wore a lens of power −10.00 diopters (D) of standard spherical optical design. The two Test lenses both had a central optical power −10.00 D, but used different peripheral myopia progression control (MPC) designs. For all groups, retinoscopy was repeated on days 3, 7, 10, and 14; ultrasound was repeated on day 14. Results.: On day 0 there was no statistical difference in refractive error (mean +6.92 D) or axial length (mean 8.06 mm) between Test and Control groups or treated and untreated eyes (all P > 0.05). At day 14, 37 (43.5%) of 85 chickens had not experienced goggle detachment and were included in the final analyses. In this cohort there was a significant refractive difference between the treated eyes of the Control group (n = 17) and those of Test 1 (n = 14) and Test 2 (n = 6) groups (both P < 0.01): Control −4.65 ± 2.11 D, Test 1 +4.57 ± 3.11 D, Test 2 +1.08 ± 1.24 D (mean ± SEM). There was also a significant axial length difference (both P < 0.01): Control 10.55 ± 0.36 mm, Test 1 9.99 ± 0.14 mm, Test 2 10.17 ± 0.18 mm. Conclusions.: Use of these unique MPC lens designs over 14 days caused a significant reduction in the development of defocus-induced myopia in chickens; the degree of reduction appeared to be design specific.

Description

Woods, J., Guthrie, S. E., Keir, N., Dillehay, S., Tyson, M., Griffin, R., … Irving, E. (2013). Inhibition of Defocus-Induced Myopia in Chickens. Investigative Opthalmology & Visual Science, 54(4), 2662. https://doi.org/10.1167/iovs.12-10742

Keywords

Myopia control, Emmetropization, Refractive error, Eye growth, Multifocal lens

LC Keywords

Citation