Thermal resistance measurement of glazing system edge-seals and seal materials using a guarded heater plate apparatus

dc.contributor.authorWright, John L.
dc.contributor.authorSullivan, Harry F.
dc.date.accessioned2017-03-22T17:59:13Z
dc.date.available2017-03-22T17:59:13Z
dc.date.issued1989
dc.description© 1989 ASHRAE (www.ashrae.org). Published in ASHRAE Transactions, Volume 95, Part 2. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission.en
dc.description.abstractIn cold climates the increased edge-glass heat transfer at the perimeter of a sealed glazing unit creates a special problem. This is where condensed water and frost most readily occur. One mechanism contributing to edge-glass heat transfer is edge-seal conduction. Very few data are available regarding the thermal resistance of the various edge-seal configurations that are commercially available. An experimental procedure has been devised whereby the thermal resistance of an edge-seal can be directly measured using a guarded heater plate apparatus. Results are reported for nine edge-seal test samples. In addition, results from similar tests provide measured thermal conductivities for four of the materials used in the construction of the edge-seal test samples and commercially available edge-seals.en
dc.description.sponsorshipEnergy efficiency technology division || Department of energy, mines and resources Canadaen
dc.identifier.otherVA-89-11-3
dc.identifier.urihttp://hdl.handle.net/10012/11578
dc.language.isoenen
dc.publisherAmerican Society of Heating, Refrigerating and Air-Conditioning Engineersen
dc.subjectMaterials scienceen
dc.subjectEnergy conservationen
dc.subjectEnergy consumptionen
dc.subjectGlazingen
dc.subjectThermal conductivityen
dc.subjectGlazing materialsen
dc.subjectDesignen
dc.subjectHeatersen
dc.subjectMeasuring instrumentsen
dc.subjectSealsen
dc.subjectTemperature measurementen
dc.subjectCoveringsen
dc.subjectBuilding systemsen
dc.subjectThermal Instrumentationen
dc.subjectEnergy utilizationen
dc.titleThermal resistance measurement of glazing system edge-seals and seal materials using a guarded heater plate apparatusen
dc.typeArticleen
dcterms.bibliographicCitationWright, J.L., Sullivan, H.F., "Thermal Resistance Measurement of Glazing System Edge-Seals and Seal Materials Using a Guarded Heater Plate Apparatus," ASHRAE Transactions, Vol 95, Pt. 2 (1989) pp. 766-771.en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
50-VA-89-11-3.pdf
Size:
1.05 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Item-specific license agreed upon to submission
Description: