The Library will be performing maintenance on UWSpace on October 2nd, 2024. UWSpace will be offline for all UW community members during this time.
 

Development of a bedside-applicable ultrasound protocol to estimate fat mass index derived from whole body dual-energy x-ray absorptiometry scans

dc.contributor.authorParis, Michael
dc.contributor.authorMourtzakis, Marina
dc.date.accessioned2023-05-10T15:57:40Z
dc.date.available2023-05-10T15:57:40Z
dc.date.issued2019-01
dc.descriptionThe final publication is available at Elsevier via https://doi.org/10.1016/j.nut.2018.04.012. © 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractObjectives: Precise measures of adiposity are difficult to obtain in clinical settings due to a lack of access to accurate and reliable techniques. The aim of this study was to develop and internally validate a bedside-applicable ultrasound protocol to estimate fat mass index. Methods: We conducted an observational cross-sectional study of 94 university and community dwelling adults who attended a single data-collection session. Adipose tissue thickness was quantified in a supine or prone position using the four-site protocol (images two anterior sites on each thigh) and the nine-site protocol (images nine anterior and posterior sites). Adipose tissue thicknesses from the four-site protocol were compared against the fat mass index that was derived from dual-energy x-ray absorptiometry scans. Subsequently, we optimized the accuracy of the four-site protocol with the addition of bedside-accessible adipose tissue thicknesses from the nine-site protocol and easily obtained covariates. Results: The four-site protocol was strongly associated (R2 = 0.65) with fat mass index but wide limits of agreement (-3.53 kg/m2 and 3.50 kg/m2) were observed using the Bland-Altman analysis. With the addition of the anterior upper arm and abdomen adipose tissue thicknesses as well as the covariates age, sex, and body mass index, the model accuracy improved (R2 = 0.93) and the Bland-Altman analysis displayed narrower limits of agreement (-1.57 kg/m2 and 1.60 kg/m2). Conclusions: This optimized protocol developed can be applied bedside and provide accurate assessments of fat mass index.en
dc.description.sponsorshipThis work was supported by Canada Graduate Scholarship (Master) - Canadian Institute of Health Research, Province of Ontario Ministry of Research and Innovation Early Researcher Award, Canada Foundation for Innovation, Natural Sciences and Engineering Research Council, and Canadian Institute of Health Research.en
dc.identifier.urihttps://doi.org/10.1016/j.nut.2018.04.012
dc.identifier.urihttp://hdl.handle.net/10012/19440
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesNutrition;
dc.subjectadipose tissueen
dc.subjectultrasounden
dc.subjectdual energy X-ray absoroptiometryen
dc.subjectadipose tissue thicknessen
dc.subjectfat massen
dc.subjectobesityen
dc.subjectbody compositionen
dc.titleDevelopment of a bedside-applicable ultrasound protocol to estimate fat mass index derived from whole body dual-energy x-ray absorptiometry scansen
dc.typeArticleen
dcterms.bibliographicCitationParis, M. T., & Mourtzakis, M. (2019). Development of a bedside-applicable ultrasound protocol to estimate fat mass index derived from whole body dual-energy X-ray absorptiometry scans. Nutrition, 57, 225–230. https://doi.org/10.1016/j.nut.2018.04.012en
uws.contributor.affiliation1Faculty of Healthen
uws.contributor.affiliation2Kinesiology and Health Sciencesen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nutrition - Paris and Mourtzakis_Dec_20_2017.pdf
Size:
313.6 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: