Corrosion performance of medical grade NiTi after laser processing

dc.contributor.authorMichael, Andrew
dc.contributor.authorPequegnat, Andrew
dc.contributor.authorWang, J.
dc.contributor.authorZhou, Y. Norman
dc.contributor.authorKhan, M. I.
dc.date.accessioned2017-12-13T16:47:52Z
dc.date.available2017-12-13T16:47:52Z
dc.date.issued2017-09-15
dc.descriptionThe final publication is available at Elsevier via http://dx.doi.org/10.1016/j.surfcoat.2017.05.092 © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractLaser processing of shape memory alloys (SMAs) has great potential to enable the multi-functionality required for complex applications. Achieving this improved functionality often requires laser processing of the SMA's with a high-energy pulse coupled with an observable decrease in the corrosion resistance, however there are discrepancies in the post-processing corrosion performance. The current study conducts a systematic investigation of Ni-44.2wt% Ti SMA with differing numbers of laser pulses and post-process surface treatments. The localized electrochemical characteristics were investigated by scanning electrochemical microscopy. X-ray photoelectron spectroscopy and Raman spectroscopy was used to determine surface composition and oxide crystallinity, while oxide stability was determined via potentiodynamic cyclic polarization. Results showed that fewer pulses were not significantly detrimental to the corrosion performance. However, increasing the number of pulses had a significant impact on oxide stability in the heat affected zone due to increased crystallinity. The post-process surface treatments restored corrosion performance to pre-processed capabilities; however, further optimization is required to achieve maximum corrosion resistance.en
dc.description.sponsorshipCanada Foundation for Innovation (CFI)en
dc.description.sponsorshipNatural Sciences and Engineering Research Council of Canada (NSERC)en
dc.identifier.urihttp://dx.doi.org/10.1016/j.surfcoat.2017.05.092
dc.identifier.urihttp://hdl.handle.net/10012/12711
dc.language.isoenen
dc.publisherElsevieren
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCorrosionen
dc.subjectLaser processingen
dc.subjectNickel-titaniumen
dc.subjectNiTien
dc.subjectShape memory alloy (SMA)en
dc.subjectSurface treatmentsen
dc.titleCorrosion performance of medical grade NiTi after laser processingen
dc.typeArticleen
dcterms.bibliographicCitationMichael, A., Pequegnat, A., Wang, J., Zhou, Y. N., & Khan, M. I. (2017). Corrosion performance of medical grade NiTi after laser processing. Surface and Coatings Technology, 324(Supplement C), 478–485. https://doi.org/10.1016/j.surfcoat.2017.05.092en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Corrosion-performance-of-medical-grade-NiTi-after-laser-processing_2017_Surface-and-Coatings-Technology-sa.pdf
Size:
1.23 MB
Format:
Adobe Portable Document Format
Description:
Post-print

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Plain Text
Description: