Effects of ionic concentration gradient on electroosmotic flow mixing in a microchannel

dc.contributor.authorPeng, Ran
dc.contributor.authorLi, Dongqing
dc.date.accessioned2017-02-09T16:32:37Z
dc.date.available2017-02-09T16:32:37Z
dc.date.issued2014-11-08
dc.descriptionThe final publication is available at Elsevier via http://dx.doi.org/10.1016/j.jcis.2014.10.061. © 2014. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractEffects of ionic concentration gradient on electroosmotic flow (EOF) mixing of one stream of a high concentration electrolyte solution with a stream of a low concentration electrolyte solution in a microchannel are investigated numerically. The concentration field, flow field and electric field are strongly coupled via concentration dependent zeta potential, dielectric constant and electric conductivity. The results show that the electric field and the flow velocity are non-uniform when the concentration dependence of these parameters is taken into consideration. It is also found that when the ionic concentration of the electrolyte solution is higher than 1 M, the electrolyte solution essentially cannot enter the channel due to the extremely low electroosmotic flow mobility. The effects of the concentration dependence of zeta potential, dielectric constant and electric conductivity on electroosmotic flow mixing are studied.en
dc.identifier.urihttp://dx.doi.org/10.1016/j.jcis.2014.10.061
dc.identifier.urihttp://hdl.handle.net/10012/11305
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesJournal of Colloid and Interface Science;440en
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFlow mixingen
dc.subjectElectroosmotic flowen
dc.subjectIonic concentrationen
dc.subjectZeta potentialen
dc.subjectDielectric constanten
dc.titleEffects of ionic concentration gradient on electroosmotic flow mixing in a microchannelen
dc.typeArticleen
dcterms.bibliographicCitationRan Peng, Dongqing Li, Effects of ionic concentration gradient on electroosmotic flow mixing in a microchannel, Journal of Colloid and Interface Science, Volume 440, 15 February 2015, Pages 126-132, ISSN 0021-9797, http://dx.doi.org/10.1016/j.jcis.2014.10.061.en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Effects of ionic concentration gradient on electroosmotic flow mixing in a microchannel.pdf
Size:
503.97 KB
Format:
Adobe Portable Document Format
Description:
Accepted Manuscript
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Item-specific license agreed upon to submission
Description: