A Comparison of Calculated and Measured Indoor-Side Window Temperature Profiles

dc.contributor.authorWright, John L.
dc.contributor.authorMcGowan, Alexander G.
dc.date.accessioned2017-03-23T19:31:39Z
dc.date.available2017-03-23T19:31:39Z
dc.date.issued2003
dc.description© 2003. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Vol. 109, Part 2. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE’s prior written permission.en
dc.description.abstractComputer-generated surface temperature profiles are presented for the indoor side, vertical centerline of two windows and a calibration transfer standard (CTS). These specific configurations were chosen because they match test specimens used in a previous test program, and the resulting temperature profiles, measured using a thermographic camera, are available in the literature. Calculations were completed using the VISION4 program for one-dimensional center-glass analysis and the FRAME 4.0 program for two-dimensional analysis of the edge-glass and frame. Three different computational models were used: (1) the conventional procedure used widely to generate total-window solar gain and heat loss coefficients, (2) a procedure to account for fill-gas motion was added, and (3) the convective heat transfer coefficients were reduced near the recessed corners of the indoor surface. Profiles were scrutinized most closely at the bottom edge-glass section-where condensation most readily occurs. Simulation provides useful qualitative information, and each of the two features added to the model provides better agreement with measurement. It is concluded that simple, inexpensive, and easy-to-use computer software can offer reliable design guidance and performance verification regarding condensation resistance.en
dc.description.sponsorshipNatural Sciences and Engineering Research Council of Canadaen
dc.identifier.otherKC-03-12-2
dc.identifier.urihttp://hdl.handle.net/10012/11590
dc.language.isoenen
dc.publisherAmerican Society of Heating, Refrigerating and Air-Conditioning Engineersen
dc.subjectFenestrationen
dc.subjectCondensation resistanceen
dc.subjectSimulationen
dc.subjectMeasurementen
dc.titleA Comparison of Calculated and Measured Indoor-Side Window Temperature Profilesen
dc.typeArticleen
dcterms.bibliographicCitationWright, J.L., McGowan, A.G., "A Comparison of Calculated and Measured Indoor-Side Window Temperature Profiles," ASHRAE Transactions, Vol. 109, Pt. 2., pp. 857-870 (2003)en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
27-KC-03-12-2.pdf
Size:
4.96 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Item-specific license agreed upon to submission
Description: