UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Decoupling of a neutron interferometer from temperature gradients

dc.contributor.authorSaggu, Parminder
dc.contributor.authorMineeva, Taisiya
dc.contributor.authorArif, Muhammad
dc.contributor.authorCory, David G.
dc.contributor.authorHaun, Robert
dc.contributor.authorHeacock, Benjamin
dc.contributor.authorHuber, Michael G.
dc.contributor.authorLi, Ke
dc.contributor.authorNsofini, Joachim
dc.contributor.authorSarenac, Dusan
dc.contributor.authorShahi, Chandra B.
dc.contributor.authorSkavysh, Vladimir
dc.contributor.authorSnow, W. Michael
dc.contributor.authorWerner, Samuel A.
dc.contributor.authorYoung, Albert R.
dc.contributor.authorPushin, Dimitry A.
dc.date.accessioned2018-09-11T19:41:21Z
dc.date.available2018-09-11T19:41:21Z
dc.date.issued2016-12-16
dc.descriptionThis article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Saggu, P., Mineeva, T., Arif, M., Cory, D. G., Haun, R., Heacock, B., … Pushin, D. A. (2016). Decoupling of a neutron interferometer from temperature gradients. Review of Scientific Instruments, 87(12), 123507. doi:10.1063/1.4971851 and may be found at https://dx.doi.org/10.1063/1.4971851en
dc.description.abstractNeutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry.en
dc.description.sponsorshipDivision of Physics: NSF PHY-1205342en
dc.identifier.urihttps://dx.doi.org/10.1063/1.4971851
dc.identifier.urihttp://hdl.handle.net/10012/13805
dc.language.isoenen
dc.publisherAIP Publishingen
dc.subjectacoustic wavesen
dc.subjectresistorsen
dc.subjectinterferometryen
dc.subjectheating elementsen
dc.subjectenvironmental noiseen
dc.subjectvacuum apparatusen
dc.subjectvacuum systemsen
dc.subjectecologyen
dc.subjectvibration isolatorsen
dc.titleDecoupling of a neutron interferometer from temperature gradientsen
dc.typeArticleen
dcterms.bibliographicCitationSaggu, P., Mineeva, T., Arif, M., Cory, D. G., Haun, R., Heacock, B., … Pushin, D. A. (2016). Decoupling of a neutron interferometer from temperature gradients. Review of Scientific Instruments, 87(12), 123507. doi:10.1063/1.4971851en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2Physics and Astronomyen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten
uws.typeOfResourceRevieweden

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1.4971851.pdf
Size:
1.31 MB
Format:
Adobe Portable Document Format
Description:
Publisher's version
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Plain Text
Description: