UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Decoupling of a neutron interferometer from temperature gradients

Loading...
Thumbnail Image

Date

2016-12-16

Authors

Saggu, Parminder
Mineeva, Taisiya
Arif, Muhammad
Cory, David G.
Haun, Robert
Heacock, Benjamin
Huber, Michael G.
Li, Ke
Nsofini, Joachim
Sarenac, Dusan

Journal Title

Journal ISSN

Volume Title

Publisher

AIP Publishing

Abstract

Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry.

Description

This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Saggu, P., Mineeva, T., Arif, M., Cory, D. G., Haun, R., Heacock, B., … Pushin, D. A. (2016). Decoupling of a neutron interferometer from temperature gradients. Review of Scientific Instruments, 87(12), 123507. doi:10.1063/1.4971851 and may be found at https://dx.doi.org/10.1063/1.4971851

Keywords

acoustic waves, resistors, interferometry, heating elements, environmental noise, vacuum apparatus, vacuum systems, ecology, vibration isolators