dc.description.abstractThe present study expands on previous building simulation work con-cerning the potential benefits of residential zoned cooling systems during peak summer days. Such zoned systems provide an opportunity for peak reduction on hot and humid days when the electricity peak is largely caused by increased space cooling demand. In the previous study, control strategies for different occupancy profiles were consid-ered and their impact on peak and cooling energy reduction were compared. The present study builds on these results by considering the benefits of shading as a passive means of reducing the peak cooling load. The analysis is based on integrated building energy simulations of a newer-vintage house using the zoned cooling system model in con-junction with the expanded set of shading models. Total cooling ener-gy demand, peak cooling power reductions and their impact on even-ing recovery times are examined. It was found that zoned control strategies alone can yield signifi-cant peak power reductions, but the long recovery periods limit their practical application. Only with between-pane or outdoor shade con-figurations can very large reductions can be realized without compro-mising occupant comfort during the evening recovery period.en
dc.language.isoenen
dc.publisherInternational Building Performance Simulation Associationen
dc.subjectFenestrationen
dc.subjectShadingen
dc.subjectBuilding simulationen
dc.subjectPeaken
dc.subjectZoneden
dc.titleMitigation of Peak Cooling Demand through the Combination of Residential Zoned Cooling and Window Shading: A Building Simulation Case Studyen
dc.typeConference Paperen
dcterms.bibliographicCitationLomanowski, B.A., Wright, J.L., "Mitigation of Peak Cooling Demand through the Combination of Residential Zoned Cooling and Window Shading: A Building Simulation Case Study", Proc. eSim 2014 Building Simulation Conference, Carleton University, Ottawa, Canada (May 7-10, 2014).en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages