UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

A Simplified Analysis of Radiant Heat Loss Through Projecting Fenestration Products

Loading...
Thumbnail Image

Date

2001

Authors

Wright, John L.

Journal Title

Journal ISSN

Volume Title

Publisher

American Society of Heating, Refrigerating and Air-Conditioning Engineers

Abstract

Current window analysis algorithms can deal with many features, including low-e coatings and substitute fill gases. These methods were developed for products with planar glazings. Results can be generated for projecting products such as greenhouse windows, but the indoor-side heat transfer coefficient must be reduced to reflect differences in convection and radiant exchange for this geometry. Two simplified models are developed for radiant heat loss to projecting windows and are shown to agree well with a pseudo three-dimensional multi-element computer-based calculation. It is confirmed that the indoor-side heat transfer coefficient does not need to be accurately known to characterize a well-insulated window. More research is needed to quantify indoor-side convective heat loss before radiant exchange models can be verified and projecting products can be well characterized in general.

Description

© 2001 ASHRAE (www.ashrae.org). Published in ASHRAE Transactions, Volume 107, Part 1. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permissio

Keywords

Projecting fenestration, U-factor, Convection, Radiant exchange