Show simple item record

dc.contributor.authorWright, John L.
dc.date.accessioned2017-03-23 19:17:55 (GMT)
dc.date.available2017-03-23 19:17:55 (GMT)
dc.date.issued1998
dc.identifier.otherSF-98-12-2
dc.identifier.urihttp://hdl.handle.net/10012/11588
dc.description© 1998 ASHRAE (www.ashrae.org). Published in ASHRAE Transactions, Volume 104, Part 1. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission.en
dc.description.abstractMethods have been established for calculating heat transfer in windows whereby a one-dimensional analysis is used for the center-glass area and a two-dimensional numerical calculation is used to model conduction in the edge-glass and frame. The effect of fill gas motion cannot be seen because the fill gas is treated as an opaque solid. The fill gas cools the bottom edge of the indoor glazing, so the predicted minimum indoor glazing temperature will consistently be too high. A detailed two-dimensional simulation of the entire window can be used but requires substantial effort. A simplified method has been devised. The flow pattern of the fill gas in the entire cavity is found using a two-dimensional computational fluid dynamics (CFD) analysis of natural convection where the wall temperatures are established using the one-dimensional center-glass model. Velocities in the edge-glass and the temperature of the fill gas entering the edge-glass section are noted. These data are used in a two-dimensional edge-glass/frame analysis. This method is not complicated and results are obtained quickly. Temperature profiles agree with experimental data and detailed numerical simulation. Sample results in this paper demonstrate the effect of fill gas motion, edge-seal conductance, a low-emissivity (low-e) coating, and argon fill gas on minimum indoor surface temperature.en
dc.description.sponsorshipNatural Resources Canada || Department of Mechanical Engineeringen
dc.language.isoenen
dc.publisherAmerican Society of Heating, Refrigerating and Air-Conditioning Engineersen
dc.subjectFenestrationen
dc.subjectCondensation resistanceen
dc.subjectNumericalen
dc.subjectSimplifed modelen
dc.titleA Simplified Numerical Method for Assessing the Condensation Resistance of Windowsen
dc.typeArticleen
dcterms.bibliographicCitationWright, J.L., "A Simplified Numerical Method for Assessing the Condensation Resistance of Windows," ASHRAE Transactions, Vol. 104, Pt. 1 (1998) pp. 1222-1229.en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Mechanical and Mechatronics Engineeringen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages