UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Comparison of model-predicted and measured moment arms for the rotator cuff muscles

dc.contributor.authorGatti, Christopher J.
dc.contributor.authorDickerson, Clark R.
dc.contributor.authorChadwick, Edward K.
dc.contributor.authorMell, Amy G.
dc.contributor.authorHughes, Richard E.
dc.date.accessioned2022-01-12T14:46:29Z
dc.date.available2022-01-12T14:46:29Z
dc.date.issued2007-07
dc.descriptionThe final publication is available at Elsevier via http://dx.doi.org/10.1016/j.clinbiomech.2007.02.001. © 2007. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractBackground The ability of mathematical models of the shoulder to accurately replicate physiological muscle moment arms is unknown. The purpose of this study was to compare model-predicted and experimentally measured moment arms for the rotator cuff muscles during arm elevation. Methods Moment arms obtained from six mathematical models and seven experimental studies were compared for the supraspinatus, infraspinatus, teres minor, and subscapularis for elevation in the scapular plane. Results All of the included models generated moment arms that generally fell within the range of experimentally measured data. Interpretation The quantitative agreement between model-predicted and experimentally measured moment arms supports the use of the included models for biomechanical shoulder analyses.en
dc.description.sponsorshipNational Institute of Healthen
dc.identifier.urihttps://dx.doi.org/10.1016/j.clinbiomech.2007.02.001
dc.identifier.urihttp://hdl.handle.net/10012/17861
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesClinical Biomechanics;
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectshoulderen
dc.subjectmoment armsen
dc.subjectcomputational modelen
dc.titleComparison of model-predicted and measured moment arms for the rotator cuff musclesen
dc.typeArticleen
dcterms.bibliographicCitationGatti, C. J., Dickerson, C. R., Chadwick, E. K., Mell, A. G., & Hughes, R. E. (2007). Comparison of model-predicted and measured moment arms for the rotator cuff muscles. Clinical Biomechanics, 22(6), 639–644. https://doi.org/10.1016/j.clinbiomech.2007.02.001en
uws.contributor.affiliation1Faculty of Applied Health Sciencesen
uws.contributor.affiliation2Kinesiologyen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Comparison_of_model-predicted_and_measured_moment_-Clark (1).pdf
Size:
367.5 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: