Integration of Combined Heat and Power Generators into Small Buildings - A Transient Analysis Approach

dc.contributor.authorDeBruyn, Adrian Bryanen
dc.date.accessioned2007-05-08T13:42:52Z
dc.date.available2007-05-08T13:42:52Z
dc.date.issued2006en
dc.date.submitted2006en
dc.description.abstractSmall combined heat and power generators have the potential to reduce energy consumption and greenhouse gas emissions of residential buildings. Recently, much attention has been given to these units. To date, the majority of studies in this field have concentrated on the steady operational performance of a specific generator type, and the available computer models have largely been theoretical in nature. <br /><br /> The main goal of this study was to evaluate the performance of the latest combined heat and power generators, when integrated into Canadian residential homes. A fair comparison of four 1 kW (electrical) units was made. The combined heat and power units studied were based on PEM fuel cell, solid oxide fuel cell, Stirling Engine, and internal combustion engine energy converters. <br /><br /> This study utilized recent test data in an attempt to evaluate the most efficient method of integrating the combined heat and power units into residential houses. Start-up, shut down, and load change transients were incorporated into the simulations. The impact of load variations due to building thermal envelope differences and varying building heating system equipment was evaluated. The simulations were evaluated using TRNSYS software. The building heat demands were determined with eQuest hourly building simulation software. <br /><br /> All of the combined heat and power units under study were capable of providing a net annual benefit with respect to global energy and greenhouse gas emissions. The fuel cells offer the highest integrated performance, followed closely by the internal combustion engine and lastly the Stirling engine. Annual global energy savings up to 20%, and greenhouse gas savings up to 5. 5 tonnes per year can be achieved compared to the best conventional high efficiency appliances. <br /><br /> Heat demand influences performance greatly. As the thermal output of the generator unit approaches half of the average building thermal demand, the system design becomes critical. The system design is also critical when integrating with a forced air furnace. Only the PEM fuel cell unit produces clear global energy and emissions benefits when operating in the summertime.en
dc.formatapplication/pdfen
dc.format.extent890522 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10012/2830
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.rightsCopyright: 2006, DeBruyn, Adrian Bryan. All rights reserved.en
dc.subjectMechanical Engineeringen
dc.subjectcogenerationen
dc.subjectfuel cellen
dc.subjectresidentialen
dc.subjecttesten
dc.subjectStirlingen
dc.subjectgeneratoren
dc.titleIntegration of Combined Heat and Power Generators into Small Buildings - A Transient Analysis Approachen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentMechanical Engineeringen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
abdebruy2006.pdf
Size:
869.65 KB
Format:
Adobe Portable Document Format