UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

An Experimental Approach Towards Characterizing the Transient Response of Drain Water Heat Recovery Systems

dc.contributor.authorDhillon, Ajmeet Singh
dc.date.accessioned2019-09-27T13:30:50Z
dc.date.available2019-09-27T13:30:50Z
dc.date.issued2019-09-27
dc.date.submitted2019-09-19
dc.description.abstractDrain Water Heat Recovery (DWHR) systems recover thermal energy from the gray water and use it to pre-heat incoming mains water. So far, the research conducted in this field has focused on the steady-state (SS) operation of DWHR systems. It has now become important to characterize the transient behaviour of DWHR systems, so that it could be included in energy simulation models. The ultimate focus of this thesis was to study the transient response of various DWHR systems, and in particular, to estimate the time it would take to reach quasi-steady-state operating conditions. The analysis was approached using two experimental methods. The first approach dealt with estimating the time dependent rate of heat recovery, based solely on the fluid inlet and outlet temperatures and flowrates. Correlations were used to estimate 63.2% and 86.5% steady-state time responses. The correlations were validated by performing random experiments. The predicted and experimental time responses were in good agreement. The second approach used infrared thermography to estimate fluid temperatures through the DWHR systems, along with estimating the time responses. This approach provided an estimation of energy storage in the DWHR during transient operation. The time responses derived by both methods were compared. It was found that both the 63.2% and 86.5% time responses increased with increasing DWHR system length and decreasing flowrate. The time responses estimated using infrared thermography were always a few seconds longer than the first approach. Recommendations were made to suggest ways to improve and build on the current work. One of the major recommendations was modification of the Heat Exchanger Test Platform (HXTP), to better facilitate transient experiments.en
dc.identifier.urihttp://hdl.handle.net/10012/15180
dc.language.isoenen
dc.pendingfalse
dc.publisherUniversity of Waterlooen
dc.subjectInfrared Thermographyen
dc.subjectHeat Exchangeren
dc.subjectThermal Imagingen
dc.subjectDrain Water Heat Recoveryen
dc.titleAn Experimental Approach Towards Characterizing the Transient Response of Drain Water Heat Recovery Systemsen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentMechanical and Mechatronics Engineeringen
uws-etd.degree.disciplineMechanical Engineeringen
uws-etd.degree.grantorUniversity of Waterlooen
uws.contributor.advisorCollins, Michael
uws.contributor.affiliation1Faculty of Engineeringen
uws.peerReviewStatusUnrevieweden
uws.published.cityWaterlooen
uws.published.countryCanadaen
uws.published.provinceOntarioen
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Dhillon_Ajmeet-Singh.pdf
Size:
12.47 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6.08 KB
Format:
Item-specific license agreed upon to submission
Description: