Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model

dc.contributor.authorBajgrowicz-Cieslak, Magdalena
dc.contributor.authorPhan, Chau-Minh
dc.contributor.authorSubbaraman, Lakshman N.
dc.contributor.authorJones, Lyndon W.
dc.date.accessioned2017-03-07T19:47:52Z
dc.date.available2017-03-07T19:47:52Z
dc.date.issued2015-10-04
dc.descriptionBajgrowicz, M., Phan, C.-M., Subbaraman, L. N., & Jones, L. (2015). Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model. Investigative Opthalmology & Visual Science, 56(4), 2234. https://doi.org/10.1167/iovs.15-16379en
dc.description.abstractPurpose.: To analyze the release of two fluoroquinolones, ciprofloxacin and moxifloxacin, from conventional hydrogel (CH) and silicone hydrogel (SH) daily disposable contact lenses (CLs), comparing release from a fixed-volume vial and a novel in vitro eye model. Methods.: Four CH CLs (nelfilcon A, omafilcon A, etafilcon A, ocufilcon B) and three SH CLs (somofilcon A, narafilcon A, delefilcon A) were used. The lenses were incubated in drug solutions for 24 hours. After the incubation period, the lenses were placed in two release conditions: (1) a vial containing 4.8 mL PBS for 24 hours and (2) an in vitro eye model with a flow rate at 4.8 mL over 24 hours. Results.: Release in the vial for both drugs was rapid, reaching a plateau between 15 minutes and 2 hours for all lenses. In contrast, under physiological flow conditions, a constant and slow release was observed over 24 hours. The amounts of ciprofloxacin released from the lenses ranged between 49.6 ± 0.7 and 62.8 ± 0.3 μg per lens in the vial, and between 35.0 ± 7.0 and 109.0 ± 5.0 μg per lens in the eye model. Moxifloxacin release ranged from 24.0 ± 4.0 to 226.0 ± 2.0 μg per lens for the vial, and between 13.0 ± 2.0 and 151.0 ± 10.0 μg per lens in the eye model. In both systems and for both drugs, HEMA-based CLs released more drugs than other materials. Conclusions.: The parameters of the release system, in particular the volume and flow rate, have a significant influence on measured release profiles. Under physiological flow, release profiles are significantly slower and constant when compared with release in a vial.en
dc.identifier.urihttp://hdl.handle.net/10012/11445
dc.identifier.urihttp://dx.doi.org/10.1167/iovs.15-16379
dc.language.isoenen
dc.publisherAssociation for Research in Vision and Ophthalmologyen
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectCiprofloxacinen
dc.subjectMoxifloxacin contact lensen
dc.subjectDrug deliveryen
dc.subjectEye modelen
dc.subjectMicrofluidicen
dc.subjectSilicone hydrogelen
dc.titleRelease of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Modelen
dc.typeArticleen
dcterms.bibliographicCitationBajgrowicz, M., Phan, C.-M., Subbaraman, L. N., & Jones, L. (2015). Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model. Investigative Opthalmology & Visual Science, 56(4), 2234. https://doi.org/10.1167/iovs.15-16379en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2School of Optometry and Vision Scienceen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
i1552-5783-56-4-2234.pdf
Size:
898.05 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Plain Text
Description: