dc.description | The final publication is available at Elsevier via http://dx.doi.org/10.1016/j.jbiomech.2018.04.044 © 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ | en |
dc.description.abstract | Side impact crashes contribute a significant number of fatal injuries (25% of road fatalities in the USA in 2016), with severe thoracic injuries diagnosed in 58% of front near-side impact occupants. Epidemiological data indicate that thoracic-only side airbags (tSABs) are not as effective as laboratory testing has suggested, and one of the reasons for this may be the use of surrogate-specific injury assessment methods, which are not directly transferable between Anthropometric Test Devices (ATDs) and Post-Mortem Human Surrogates (PMHSs). This study examines the effect of the thorax deformation measurement location and method on the predicted performance of seatbelts and tSABs in a side impact using a Human Body Model (HBM). The HBM was integrated in a vehicle and subjected to a Moving Deformable Barrier (MDB) impact at 61 km/h, with four restraint configurations: belted and unbelted, with and without a tSAB. Occupant response was assessed through chest band (CB) deformation, and as a change in distance between markers on the ribs. Multiple measurement locations in the HBM enabled direct comparison between the methods. The CB method indicated a 35% increase of chest compression due to tSAB; the rib-deflection (RD) method was not sensitive to the tSAB. The RD method predicted a 20% reduction of chest compression due to the seatbelt, but the CB-measured change was negligible. This study highlights the importance of measurement method on the response outcome and demonstrates that different outcomes may be predicted using a HBM for the same impact scenario, depending on the measurement method. | en |
dc.description.sponsorship | Natural Sciences and Engineering Research Council of Canada | en |
dc.identifier.uri | https://doi.org/10.1016/j.jbiomech.2018.04.044 | |
dc.identifier.uri | http://hdl.handle.net/10012/13440 | |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Finite element method | en |
dc.subject | Human body model | en |
dc.subject | Injury biomechanics | en |
dc.subject | Passive restraints | en |
dc.subject | Side impacts | en |
dc.title | Influence of the chest compression measurement method on assessment of restraint performance in side-impact crash scenarios | en |
dc.type | Article | en |
dcterms.bibliographicCitation | Gierczycka, D., & Cronin, D. (2018). Influence of the chest compression measurement method on assessment of restraint performance in side-impact crash scenarios. Journal of Biomechanics, 75, 53–57. https://doi.org/10.1016/j.jbiomech.2018.04.044 | en |
uws.contributor.affiliation1 | Faculty of Engineering | en |
uws.contributor.affiliation2 | Mechanical and Mechatronics Engineering | en |
uws.peerReviewStatus | Reviewed | en |
uws.scholarLevel | Faculty | en |
uws.typeOfResource | Text | en |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 1-s2.0-S0021929018303452-main.pdf
- Size:
- 773.77 KB
- Format:
- Adobe Portable Document Format
- Description:
- Post-print
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 6.08 KB
- Format:
- Item-specific license agreed upon to submission
- Description: