The Library will be performing maintenance on UWSpace on October 2nd, 2024. UWSpace will be offline for all UW community members during this time.
 

Ultrasound image resolution influences analysis of skeletal muscle composition

dc.contributor.authorParis, Michael
dc.contributor.authorBell, Kirsten Elizabeth
dc.contributor.authorAvrutin, Egor
dc.contributor.authorMourtzakis, Marina
dc.date.accessioned2023-05-10T13:41:42Z
dc.date.available2023-05-10T13:41:42Z
dc.date.issued2020-06-03
dc.descriptionThis is the peer reviewed version of the following article: Paris, M. T., Bell, K. E., Avrutin, E., & Mourtzakis, M. (2020). Ultrasound image resolution influences analysis of skeletal muscle composition. Clinical Physiology and Functional Imaging, 40(4), 277–283, which has been published in final form at https://doi.org/10.1111/cpf.12636. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.en
dc.description.abstractIntroduction: Analysis of muscle composition using ultrasound requires standardization of several equipment settings (i.e. gain). However, the influence of image resolution, which is altered by imaging depth, on measures of muscle composition is unknown. Methods: We analysed rectus femoris muscle composition using ultrasound images captured from 32 males and females (aged 28 ± 5 years) at depths of 9.0, 7.3, 5.9 and 4.7 cm. The transducer's orientation was fixed using a clamp during image acquisition to minimize movement. Across each image resolution, a region of interest encompassing the same anatomical area within the muscle was used for muscle composition analysis. Muscle composition was analysed using a combination of first-, second- and higher-order texture features. Muscle composition agreement across image resolutions was evaluated using a one-way ANOVA and intraclass correlation coefficients (ICC). Results: Most muscle composition features displayed differences due to image resolution (p < .05). ICCs demonstrated poor-to-good agreement across different image resolutions. In general, higher resolution images (i.e. shallower imaging depth) demonstrated better agreement (ICC > 0.90) compared to lower resolution images. Conclusions: Ultrasound image resolution influences muscle composition analysis. Image resolution should be fixed within and between individuals when evaluating muscle composition using ultrasound.en
dc.description.sponsorshipThis research was funded by the University of Waterloo's Network for Aging Researchen
dc.identifier.urihttps://doi.org/10.1111/cpf.12636
dc.identifier.urihttp://hdl.handle.net/10012/19432
dc.language.isoenen
dc.publisherWileyen
dc.relation.ispartofseriesClinical Physiology and Functional Imaging;
dc.subjectultrasounden
dc.subjectmuscle compositionen
dc.subjectecho intensityen
dc.subjectbody compositionen
dc.subjectechogenicityen
dc.subjectmuscle qualityen
dc.subjectskeletal muscle compositionen
dc.titleUltrasound image resolution influences analysis of skeletal muscle compositionen
dc.typeArticleen
dcterms.bibliographicCitationParis, M. T., Bell, K. E., Avrutin, E., &amp; Mourtzakis, M. (2020). Ultrasound image resolution influences analysis of skeletal muscle composition. Clinical Physiology and Functional Imaging, 40(4), 277–283. https://doi.org/10.1111/cpf.12636en
uws.contributor.affiliation1Faculty of Healthen
uws.contributor.affiliation2Kinesiology and Health Sciencesen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Paris et al. CPFI 2020 - combined.pdf
Size:
1.43 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: