UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

The impact of compressive force magnitude on the in vitro neutral zone range and passive stiffness during a flexion–extension range of motion test

dc.contributor.authorNoguchi, Mamiko
dc.contributor.authorGooyers, Chad Edward
dc.contributor.authorHolmes, Michael W.R.
dc.contributor.authorCallaghan, Jack P.
dc.date.accessioned2017-03-21T19:26:37Z
dc.date.available2017-03-21T19:26:37Z
dc.date.issued2015-02-23
dc.descriptionNoguchi, M., Gooyers, C. E., Holmes, M. W. R., & Callaghan, J. P. (2015). The impact of compressive force magnitude on the in vitro neutral zone range and passive stiffness during a flexion-extension range of motion test. Cogent Engineering, 2(1). https://doi.org/10.1080/23311916.2015.1014253en
dc.description.abstractThe objective of this work was to examine the influence of compressive force magnitude on a functional spinal unit’s (FSU) flexion–extension neutral zone measured during pure moment (PM) tests. Each porcine cervical FSU received four repeats of a PM test with 10, 300, 900 and 1,800 N of compressive force, in a randomized order. Increasing the magnitude of compression significantly decreased the neutral zone range (p < 0.001), while increasing passive stiffness (p < 0.001). The flexion limit at 10 N was significantly lower (p < 0.05) than the other loading conditions. Reporting the compressive force magnitude is important when posture is a standardized experimental factor considered in the design of in vitro spine biomechanics studies.en
dc.description.sponsorshipThe authors acknowledge partial funding from the Natural Science and Engineering Research Council of Canada (NSERC). Dr. Jack Callaghan is supported by the Canada Research Chair in Spine Biomechanics and Injury Preventionen
dc.identifier.urihttp://dx.doi.org/10.1080/23311916.2015.1014253
dc.identifier.urihttp://hdl.handle.net/10012/11558
dc.language.isoenen
dc.publisherTaylor & Francisen
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectNeutral zoneen
dc.subjectPassive stiffnessen
dc.subjectCompressionen
dc.subjectFlexion–extension range of motion testen
dc.subjectIn vitroen
dc.titleThe impact of compressive force magnitude on the in vitro neutral zone range and passive stiffness during a flexion–extension range of motion testen
dc.typeArticleen
dcterms.bibliographicCitationNoguchi, M., Gooyers, C. E., Holmes, M. W. R., & Callaghan, J. P. (2015). The impact of compressive force magnitude on the in vitro neutral zone range and passive stiffness during a flexion-extension range of motion test. Cogent Engineering, 2(1). https://doi.org/10.1080/23311916.2015.1014253en
uws.contributor.affiliation1Faculty of Applied Health Sciencesen
uws.contributor.affiliation2Department of Kinesiologyen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
23311916.2015.1014253.pdf
Size:
531.34 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Plain Text
Description: