A Correlation to Quantify Convective Heat Transfer Between Vertical Window Glazings
Loading...
Date
1996
Authors
Wright, John L.
Advisor
Journal Title
Journal ISSN
Volume Title
Publisher
American Society of Heating, Refrigerating and Air-Conditioning Engineers
Abstract
Several correlations have been used in recent years for the purpose of calculating convective, centre-glass heat transfer rates across gas-filled interpane window cavities. These correlations are examined and their background discussed. The most recent experimental data are gathered and presented. These data were used to develop a new correlation specifically for the purpose of window analysis. The new correlation is not restricted to conditions customarily encountered in window applications (i.e., low Rayleigh number, high aspect ratio). It also is valid with respect to applications involving low aspect ratio (i.e., windows with wide pane spacing or narrow spacing with muntin bars) and/or applications involving high Rayleigh number (e.g., wide pane spacing, krypton fill gas).
Description
© 1996. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Vol. 102, Part 1. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE’s prior written permission.
Keywords
Convection, Heat flow, Glazing, Calculating, Double glazing, Windows, Vertical window glazings, Fenestration, Natural convection, Tall cavity