Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model
dc.contributor.author | Yeow, John | |
dc.contributor.author | Ben Daya, Ibrahim | |
dc.contributor.author | CHEN, ALBERT I-HSIANG | |
dc.contributor.author | Shafiee, Mohammad Javad | |
dc.contributor.author | Wong, Alexander | |
dc.date.accessioned | 2017-02-10T20:26:49Z | |
dc.date.available | 2017-02-10T20:26:49Z | |
dc.date.issued | 2015-12-11 | |
dc.description | Ben Daya I, Chen AIH, Shafiee MJ, Wong A, Yeow JTW (2015) Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model. PLoS ONE 10(12): e0142817. doi:10.1371/journal.pone.0142817 | en |
dc.description.abstract | 3-D ultrasound imaging offers unique opportunities in the field of non destructive testing that cannot be easily found in A-mode and B-mode images. To acquire a 3-D ultrasound image without a mechanically moving transducer, a 2-D array can be used. The row column technique is preferred over a fully addressed 2-D array as it requires a significantly lower number of interconnections. Recent advances in 3-D row-column ultrasound imaging systems were largely focused on sensor design. However, these imaging systems face three intrinsic challenges that cannot be addressed by improving sensor design alone: speckle noise, sparsity of data in the imaged volume, and the spatially dependent point spread function of the imaging system. In this paper, we propose a compensated row-column ultrasound image reconstruction system using Fisher-Tippett multilayered conditional random field model. Tests carried out on both simulated and real row-column ultrasound images show the effectiveness of our proposed system as opposed to other published systems. Visual assessment of the results show our proposed system’s potential at preserving detail and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal to Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging. | en |
dc.description.sponsorship | This research was funded by the Natural Sciences and Engineering Research Council of Canada, the Canada Research Chairs Program, and the Ontario Ministry of Research and Innovation. | en |
dc.identifier.uri | http://dx.doi.org/10.1371/journal.pone.0142817 | |
dc.identifier.uri | http://hdl.handle.net/10012/11306 | |
dc.language.iso | en | en |
dc.publisher | PLOS | en |
dc.relation.ispartofseries | PLoS ONE;10(12) | en |
dc.relation.uri | https://doi.org/10.6084/m9.figshare.1593021.v1 | en |
dc.rights | Attribution 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.subject | Ultrasound imaging | en |
dc.subject | Data acquisition | en |
dc.subject | Simulation and modeling | en |
dc.subject | Optimization | en |
dc.subject | Quantiative analysis | en |
dc.subject | Random variables | en |
dc.subject | Image processing | en |
dc.subject | Signal to noise ratio | en |
dc.title | Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model | en |
dc.type | Article | en |
dcterms.bibliographicCitation | Ben Daya I, Chen AIH, Shafiee MJ, Wong A, Yeow JTW (2015) Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model. PLoS ONE 10(12): e0142817. doi:10.1371/journal.pone.0142817 | en |
uws.contributor.affiliation1 | Faculty of Engineering | en |
uws.contributor.affiliation2 | Systems Design Engineering | en |
uws.peerReviewStatus | Reviewed | en |
uws.scholarLevel | Faculty | en |
uws.typeOfResource | Text | en |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Yeow-John_Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett.pdf
- Size:
- 2.47 MB
- Format:
- Adobe Portable Document Format
- Description:
- Publisher's version
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 4.46 KB
- Format:
- Item-specific license agreed upon to submission
- Description: