Show simple item record

dc.contributor.authorZengin, Halit
dc.date.accessioned2015-07-22 12:01:59 (GMT)
dc.date.available2015-07-22 12:01:59 (GMT)
dc.date.issued2015-07-22
dc.date.submitted2015
dc.identifier.urihttp://hdl.handle.net/10012/9477
dc.description.abstractActive intelligent walkers (i-walkers) are promising to provide stable and efficient motion to people with walking disabilities. There are three focuses in this thesis: system modelling, controller design, and instrumentation of an active type i-walker system considering interaction with human user as well. Two different control oriented system models and one high-fidelity model are proposed. All system models are designed as having two-body kinematics and consider the physical human-walker interaction (pHWI) based on the user gait dynamics and characteristics. The two-body kinematics of the systems define the relative motion of the user body with the i-walker. The dynamic models of control oriented systems are developed as single-body i-walker dynamics with human effect. These single-body models are classified as symmetric vs. asymmetric, and designed considering the vertical force components of pHWI on the i-walker. The symmetric model is developed for the center of gravity (CG) displacement of the i-walker human system only along the symmetric axis. The asymmetric model is more comprehensive than the symmetric one including the lateral CG displacement as well. The high-fidelity model considers the effect of human user as a separate dynamic body and covers the horizontal and vertical force components of pHWI during walking. Different control schemes are designed for each of the models with single-body dynamics, demonstrating the characteristics and efficiency of each model. All of these control designs are based on the same inverse kinematic controller, which utilizes two-body kinematic model and provides the desired i-walker velocities regarding the user motion intention. Each of the aforementioned dynamic controllers is designed to generate the torques required to track these desired velocities. Two different dynamic control schemes are proposed for dynamic controller: Proportional-integral-derivative (PID) and sliding mode controllers. The designed controllers are simulation tested in MATLAB/Simulink for the control oriented models. The asymmetric model parameters are also set for two different type of users with symmetric and asymmetric gait patterns, respectively. Finally, instrumentation of i-walkers for implementing the designed controllers is discussed, including presentation of a new human motion detection technique involving laser range finder (LRF) and encoders, and instrumentation is performed regarding the designed controllers.en
dc.language.isoenen
dc.publisherUniversity of Waterloo
dc.subjectIntelligent walkeren
dc.subjectrobust nonlinear controlen
dc.subjectdynamic modellingen
dc.subjectnonholonomic differential mobile platformen
dc.titleControl Oriented System Modelling and Instrumentation of Intelligent Walker-Human Systemsen
dc.typeMaster Thesisen
dc.pendingfalse
dc.subject.programMechanical Engineeringen
uws-etd.degree.departmentMechanical and Mechatronics Engineeringen
uws-etd.degreeMaster of Applied Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages