Show simple item record

dc.contributor.authorMa, Tianchi
dc.date.accessioned2014-10-24 20:16:43 (GMT)
dc.date.available2014-10-24 20:16:43 (GMT)
dc.date.issued2014-10-24
dc.date.submitted2014
dc.identifier.urihttp://hdl.handle.net/10012/8920
dc.description.abstractMicro-Total-Analysis-Systems (µTAS) for genetic diagnosis have a great potential to revolutionize the future of health care. However the lack of µTAS, which is fully integrated, mass-producible and application oriented, has delayed µTAS development in real life application. In this work, I developed designs, protocols and supporting infrastructures for a polymer-based, fully integrable genetic diagnosis system capable of the Polymerase Chain Reaction (PCR) and Capillary Electrophoresis (CE). Each individual module could be integrated through a novel valve/pumping design and is fully capable of hand-free operation. These modules have been demonstrated to have a separation similar to our previous generation glass-based chips, which have previously proved the capability of genetic diagnosis. The integrated PCR module has demonstrated the concept of a CMOS compatible PCR system that is capable of mass-production. These discrete PCR modules are rapid prototypes. Using laser-based and milling machine-based rapid prototyping methods, the fabrication processes and module designs were developed. During this, the designs were studied through simulations and back-of-the-envelope (BOE) calculations. At the time of writing, the valving, PCR and CE modules have been successfully tested (with publications in print, in press and underway). In addition, a valving and CE combination has also been successfully demonstrated for a restriction fragment length polymorphism (RFLP) diagnostic and submitted for publication. All of these designs were intended to be developed in a manner that could be implemented in a PMMA chip, or on a future CMOS chip for greater cost reduction. This work has developed some of the key technologies for PCR-CE in a way that is scalable to such a CMOS system, notably with valves that can be used in a hybrid PMMA/CMOS system, and in testing a silicon based and robust temperature control system that could be implemented on CMOS.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectPolymerase Chain Reactionen
dc.subjectCapillary Electrophoresisen
dc.subjectMicro-Total-Analysis-Systemen
dc.titleAn Integrated Polymer Based Polymerase Chain Reaction And Capillary Electrophoresis System For Genetic Diagnosisen
dc.typeMaster Thesisen
dc.pendingfalse
dc.subject.programElectrical and Computer Engineering (Nanotechnology)en
uws-etd.degree.departmentElectrical and Computer Engineeringen
uws-etd.degreeMaster of Applied Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages