Show simple item record

dc.contributor.authorVeronique, Delisle
dc.date.accessioned2008-01-18 18:25:13 (GMT)
dc.date.available2008-01-18 18:25:13 (GMT)
dc.date.issued2008-01-18T18:25:13Z
dc.date.submitted2008
dc.identifier.urihttp://hdl.handle.net/10012/3494
dc.description.abstractIn the last few years, unglazed transpired solar collectors (UTCs) have proven to be an effective and viable method of reducing HVAC loads and building energy consumption. With the growing interest in PV/Thermal collectors, a study of a PV/Thermal UTC with PV cells mounted directly on the absorber was carried out. In the first part of this project, a TRNSYS model was developed to predict the performance of a PV/Thermal UTC. It was based on an actual UTC model, but modifications were made to account for the wind, the presence of PV cells and the corrugated shape of the plate. Simulations showed that mounting the cells only on the top surfaces of the corrugations prevented the cells from being shaded by the collector and consequently, presented the greatest potential. With this configuration, it was found that the addition of PV cells on the UTC decreased the thermal energy savings by 5.9 %, but that 13.6 % of the thermal energy savings could be recovered in the production of electricity. In the second part of the study, a prototype of a PV/Thermal UTC was constructed and tested outdoors. It was found that 10 % more electricity was obtained when the fan was turned on than for zero flow conditions. It was also observed that at greater air suction rates, more cooling of the panel was achieved and potentially higher electrical power could be produced. The effect of the PV cells on the collector thermal performance could not be quantified, however, due to the small portion of PV cells on the whole collector area. TRNSYS simulations were performed using the prototype parameters and the weather data of some experimental days. The results predicted by the component developed showed similar trends as the experimental results. The predictions were, however, not within the experimental uncertainties. The deviation in the results was attributed to the fact that the wind heat losses were not estimated accurately by the model and the non-uniform suction at the panel surface that prevented the prototype tested to work at its optimal performance.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectUTCen
dc.subjectPV/Thermalen
dc.titleAnalytical and Experimental Study of a PV/Thermal Transpired Collectoren
dc.typeMaster Thesisen
dc.pendingfalseen
dc.subject.programMechanical Engineeringen
uws-etd.degree.departmentMechanical and Mechatronics Engineeringen
uws-etd.degreeMaster of Applied Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages