Show simple item record

dc.contributor.authorHe, Jiayuan
dc.contributor.authorSheng, Xinjun
dc.contributor.authorZhu, Xiangyang
dc.contributor.authorJiang, Chaozhe
dc.contributor.authorJiang, Ning
dc.date.accessioned2018-09-13 13:38:27 (GMT)
dc.date.available2018-09-13 13:38:27 (GMT)
dc.date.issued2018-09-10
dc.identifier.urihttps://doi.org/10.1109/TII.2018.2869394
dc.identifier.urihttp://hdl.handle.net/10012/13808
dc.description© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.en
dc.description.abstractAutomatic gesture recognition (AGR) is investigated as an effortless human-machine interaction method, potentially applied in many industrial sectors. When using surface electromyogram (sEMG) for AGR, i.e. myoelectric control, a minimum of four EMG channels are required. However, in practical applications, fewer number of electrodes is always preferred, particularly for mobile and wearable applications. No published research focused on how to improve the performance of a myoelectric system with only two sEMG channels. In this study, we presented a systematic investigation to fill this gap. Specifically, we demonstrated that through spatial filtering and electrode position optimization, the myoelectric control performance was significantly improved (p < 0.05) and similar to that with four electrodes. Further, we found a significant correlation between offline and online performance metrics in the two-channel system, indicating that offline performance was transferable to online performance, highly relevant for algorithm development for sEMG-based AGR applications.en
dc.description.sponsorshipNatural Sciences and Engineering Research Council of Canada || (Discovery Grant 072169) National Natural Science Foundation of China || (Grant 51620105002 and 91748119) State Key Lab of Railway Control and Safety Open Topics Fund of China || (Grant RCS2017K008).en
dc.language.isoenen
dc.publisherInstitute of Electrical and Electronics Engineersen
dc.subjectAutomatic gesture recognitionen
dc.subjectElectrodesen
dc.subjectelectromyogram (EMG)en
dc.subjectError analysisen
dc.subjectGesture recognitionen
dc.subjectInformaticsen
dc.subjectMeasurementen
dc.subjectmyoelectric controlen
dc.subjectOptimizationen
dc.subjectpattern recognitionen
dc.subjectWristen
dc.titleSpatial Information Enhances Myoelectric Control Performance with Only Two Channelsen
dc.typeArticleen
dcterms.bibliographicCitationHe, J., Sheng, X., Zhu, X., Jiang, C., & Jiang, N. (2018). Spatial Information Enhances Myoelectric Control Performance with Only Two Channels. IEEE Transactions on Industrial Informatics, 1–1. https://doi.org/10.1109/TII.2018.2869394en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Systems Design Engineeringen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages