Show simple item record

dc.contributor.authorDe Grazia, Selenia
dc.contributor.authorGionfriddo, Emanuela
dc.contributor.authorPawliszyn, Janusz
dc.date.accessioned2017-10-16 13:37:27 (GMT)
dc.date.available2017-10-16 13:37:27 (GMT)
dc.date.issued2017-05-15
dc.identifier.urihttp://dx.doi.org/10.1016/j.talanta.2017.01.064
dc.identifier.urihttp://hdl.handle.net/10012/12541
dc.descriptionThe final publication is available at Elsevier via http://dx.doi.org/10.1016/j.talanta.2017.01.064 © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractThe current work presents the optimization of a protocol enabling direct extraction of avocado samples by a new Solid Phase Microextraction matrix compatible coating. In order to further extend the coating life time, pre-desorption and post-desorption washing steps were optimized for solvent type, time, and degree of agitation employed. Using optimized conditions, lifetime profiles of the coating related to extraction of a group of analytes bearing different physical-chemical properties were obtained. Over 80 successive extractions were carried out to establish coating efficiency using PDMS/DVB 65 mu m commercial coating in comparison with the PDMS/DVB/ PDMS. The PDMS/DVB coating was more prone to irreversible matrix attachment on its surface, with consequent reduction of its extractive performance after 80 consecutive extractions. Conversely, the PDMS/DVB/PDMS coating showed enhanced inertness towards matrix fouling due to its outer smooth PDMS layer. This work represents the first step towards the development of robust SPME methods for quantification of contaminants in avocado as well as other fatty-based matrices, with minimal sample pre-treatment prior to extraction. In addition, an evaluation of matrix components attachment on the coating surface and related artifacts created by desorption of the coating at high temperatures in the GC-injector port, has been performed by GCxGC-ToF/MS.en
dc.description.sponsorshipNatural Sciences and Engineering Research Council of Canada (NSERC)en
dc.description.sponsorshipSigma-Aldrich Corp.en
dc.language.isoenen
dc.publisherElsevieren
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMatrix-compatible SPME coatingen
dc.subjectDirect immersionen
dc.subjectAvocadoen
dc.subjectExtended lifetimeen
dc.subjectPDMS/DVB/PDMSen
dc.titleA new and efficient Solid Phase Microextraction approach for analysis of high fat content food samples using a matrix-compatible coatingen
dc.typeArticleen
dcterms.bibliographicCitationDe Grazia, S., Gionfriddo, E., & Pawliszyn, J. (2017). A new and efficient Solid Phase Microextraction approach for analysis of high fat content food samples using a matrix-compatible coating. Talanta, 167, 754–760. https://doi.org/10.1016/j.talanta.2017.01.064en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2Chemistryen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International

UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages