UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Numerical Simulation and Experimental Validation of Calibrant-Loaded Extraction Phase Standardization Approach

Loading...
Thumbnail Image

Date

2016-09-06

Authors

Alam, Md. Nazmul
Pawliszyn, Janusz

Journal Title

Journal ISSN

Volume Title

Publisher

American Chemical Society

Abstract

We present the kinetics of calibrant release and analyte uptake between the sample and calibrant-loaded extraction phase, CL-EP, with a finite-element analysis (FEA) using COMSOL Multiphysics software package. Effect of finite and infinite sample volume conditions, as well as various sample environment parameters such as fluid flow velocity, temperature, and presence of a binding matrix component were investigated in detail with the model in relation to the performance of the calibration. The simulation results supported by experimental data demonstrate the suitability of the CL-EP method for analysis of samples with variation of the sample environment parameters. The calibrant-loaded approach can provide both total and free concentrations from a single experiment based on whether the partition coefficient (Kes) value being used is measured in a matrix-matched sample or in a matrix-free sample, respectively. Total concentrations can also be obtained by utilizing CL-EP in combination with external matrix-matched calibrations, which can be employed to automate the sampling process and provide corrections for variations in sample preparation, matrix effects, and detection processes. This approach is also suitable for very small volumes of sample, where addition of an internal standard in the sample is either troublesome or can change the sample characteristics.

Description

This is an open access article published under an ACS AuthorChoice License, which permits copying and redistribution of the article or any adaptations for non-commercial purposes.http://pubs.acs.org/page/policy/authorchoice_termsofuse.html. This document appeared in final form in Analytical Chemistry, copyright © American Chemical Society http://dx.doi.org/10.1021/acs.analchem.6b01802

Keywords

Hydrophobic Organic Contaminants, Polyethylene Passive Samplers, Microextraction Spme, Kinetic Calibration, Water, Chemicals, Transport, Binding, Fiber, Time