Show simple item record

dc.contributor.authorBandlitz, Stefan
dc.contributor.authorPurslow, Christine
dc.contributor.authorMurphy, Paul J.
dc.contributor.authorPult, Heiko
dc.date.accessioned2017-03-10 13:52:37 (GMT)
dc.date.available2017-03-10 13:52:37 (GMT)
dc.date.issued2014-09-01
dc.identifier.urihttp://hdl.handle.net/10012/11473
dc.identifier.urihttp://dx.doi.org/10.1097/OPX.0000000000000358
dc.descriptionThis is a non-final version of an article published in final form in: Bandlitz, S., Purslow, C., Murphy, P. J., & Pult, H. (2014). The Relationship between Tear Meniscus Regularity and Conjunctival Folds: Optometry and Vision Science, 91(9), 1037–1044. https://doi.org/10.1097/OPX.0000000000000358en
dc.description.abstractPurpose: To investigate the capability of a new portable digital meniscometer (PDM) to measure tear meniscus radius (TMR) and tear meniscus height (TMH) at different locations along the lower lid and to evaluate relationships between tear meniscus regularity and the degree of lid-parallel conjunctival folds (LIPCOFs). Methods: Using the PDM, the TMR and TMH of 42 subjects were measured at three locations along the lower lid of one eye: central, perpendicularly below the pupil center (TMR-C, TMH-C), and temporal (TMR-T, TMH-T) and nasal (TMR-N, TMH-N), perpendicularly below the limbus. Nasal and temporal LIPCOF grades were recorded. Correlations between the measurements were analyzed using the Pearson coefficient (or Spearman rank in nonparametric data), and the differences were evaluated by paired t tests or analysis of variance and post hoc Fisher least significant difference test. Results: Temporal TMR was 0.041 mm flatter (p = 0.002) and TMH-T was 0.063 mm higher (p < 0.001), whereas TMR-N was 0.026 mm flatter (p = 0.038) and TMH-N was 0.046 mm higher (p < 0.001) than TMR-C and TMH-C. Temporal LIPCOF grades were significantly correlated to temporal alterations in TMH (r = 0.590; p < 0.001) and TMR (r = 0.530; p < 0.001), and nasal LIPCOF grades were significantly correlated to nasal alterations in TMH (r = 0.492; p = 0.001) and TMR (r = 0.350; p = 0.023). Conclusions: The PDM is able to noninvasively detect significant differences in TMR and TMH along the lower lid. The flatter TMR and higher TMH at the nasal and temporal locations are associated with increased LIPCOF. Because increased LIPCOF scores may affect tear film disruption along the lower lid, measuring TMR and TMH at the central position below the pupil may provide the best intersubject reliability.en
dc.language.isoenen
dc.publisherWolters Kluweren
dc.subjectTear meniscus regularityen
dc.subjectLid-parallel conjunctival foldsen
dc.subjectLIPCOFen
dc.subjectPortable digital meniscometeren
dc.subjectTear volumeen
dc.subjectReflective meniscometryen
dc.titleThe Relationship between Tear Meniscus Regularity and Conjunctival Foldsen
dc.typeArticleen
dcterms.bibliographicCitationBandlitz, S., Purslow, C., Murphy, P. J., & Pult, H. (2014). The Relationship between Tear Meniscus Regularity and Conjunctival Folds: Optometry and Vision Science, 91(9), 1037–1044. https://doi.org/10.1097/OPX.0000000000000358en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2School of Optometry and Vision Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages