UWSpace will be migrating to a new version of its software from July 29th to August 1st. UWSpace will be offline for all UW community members during this time.

Show simple item record

dc.contributor.authorZhou, Jiawei
dc.contributor.authorMcNeill, Suzanne
dc.contributor.authorBabu, Raiju Jacob
dc.contributor.authorBaker, Daniel H.
dc.contributor.authorBobier, William
dc.contributor.authorHess, Robert F.
dc.date.accessioned2017-02-22 14:48:04 (GMT)
dc.date.available2017-02-22 14:48:04 (GMT)
dc.date.issued2014-07
dc.identifier.urihttp://dx.doi.org/4098-4104. doi: 10.1167/iovs.14-13969
dc.identifier.urihttp://hdl.handle.net/10012/11326
dc.descriptionThis is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited, used for non-commercial purposes, and is not altered or transformed. Original publication: Zhou, J., McNeill, S., Babu, R. J., Baker, D. H., Bobier, W. R., & Hess, R. F. (2014). Time Course of Dichoptic Masking in Normals and Suppression in Amblyopes. Investigative Opthalmology & Visual Science, 55(7), 4098. https://doi.org/10.1167/iovs.14-13969en
dc.description.abstractPurpose.: To better understand the relationship between dichoptic masking in normal vision and suppression in amblyopia we address three questions: First, what is the time course of dichoptic masking in normals and amblyopes? Second, is interocular suppression low-pass or band-pass in its spatial dependence? And third, in the above two regards, is dichoptic masking in normals different from amblyopic suppression? Methods.: We measured the dependence of dichoptic masking in normal controls and amblyopes on the temporal duration of presentation under three conditions; monocular (the nontested eye—i.e., dominant eye of normals or nonamblyopic eye of amblyopes, being patched), dichoptic-luminance (the nontested eye seeing a mean luminance—i.e., a DC component) and dichoptic-contrast (the nontested eye seeing high-contrast visual noise). The subject had to detect a letter in the other eye, the contrast of which was varied. Results.: We found that threshold elevation relative to the patched condition occurred in both normals and amblyopes when the nontested eye saw either 1/f or band-pass filtered noise, but not just mean luminance (i.e., there was no masking from the DC component that corresponds to a channel responsive to a spatial frequency of 0 cyc/deg); longer presentation of the target (corresponding to lower temporal frequencies) produced greater threshold elevation. Conclusions.: Dichoptic masking exhibits similar properties in both subject groups, being low-pass temporally and band-pass spatially, so that masking was greatest at the longest presentation durations and was not greatly affected by mean luminance in the nontested eye.en
dc.description.sponsorshipCanadian Institutes of Health Research || Grant #53346 (RFH).en
dc.language.isoenen
dc.publisherAssociation of Research in Vision and Ophthalmologyen
dc.relation.ispartofseriesInvestigative Ophthalmology & Visual Science;55:7en
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEye Movementsen
dc.subjectStrabismusen
dc.subjectAmblyopiaen
dc.subjectNeuro-ophthalmologyen
dc.titleTime Course of Dichoptic Masking in Normals and Suppression in Amblyopesen
dc.typeArticleen
dcterms.bibliographicCitationJiawei Zhou, Suzanne McNeill, Raiju J. Babu, Daniel H. Baker, William R. Bobier, Robert F. Hess; Time Course of Dichoptic Masking in Normals and Suppression in Amblyopes. Invest. Ophthalmol. Vis. Sci. 2014;55(7):4098-4104. doi: 10.1167/iovs.14-13969.en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2School of Optometry and Vision Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International

UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages