Time Course of Dichoptic Masking in Normals and Suppression in Amblyopes

dc.contributor.authorZhou, Jiawei
dc.contributor.authorMcNeill, Suzanne
dc.contributor.authorBabu, Raiju Jacob
dc.contributor.authorBaker, Daniel H.
dc.contributor.authorBobier, William
dc.contributor.authorHess, Robert F.
dc.date.accessioned2017-02-22T14:48:04Z
dc.date.available2017-02-22T14:48:04Z
dc.date.issued2014-07
dc.descriptionThis is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited, used for non-commercial purposes, and is not altered or transformed. Original publication: Zhou, J., McNeill, S., Babu, R. J., Baker, D. H., Bobier, W. R., & Hess, R. F. (2014). Time Course of Dichoptic Masking in Normals and Suppression in Amblyopes. Investigative Opthalmology & Visual Science, 55(7), 4098. https://doi.org/10.1167/iovs.14-13969en
dc.description.abstractPurpose.: To better understand the relationship between dichoptic masking in normal vision and suppression in amblyopia we address three questions: First, what is the time course of dichoptic masking in normals and amblyopes? Second, is interocular suppression low-pass or band-pass in its spatial dependence? And third, in the above two regards, is dichoptic masking in normals different from amblyopic suppression? Methods.: We measured the dependence of dichoptic masking in normal controls and amblyopes on the temporal duration of presentation under three conditions; monocular (the nontested eye—i.e., dominant eye of normals or nonamblyopic eye of amblyopes, being patched), dichoptic-luminance (the nontested eye seeing a mean luminance—i.e., a DC component) and dichoptic-contrast (the nontested eye seeing high-contrast visual noise). The subject had to detect a letter in the other eye, the contrast of which was varied. Results.: We found that threshold elevation relative to the patched condition occurred in both normals and amblyopes when the nontested eye saw either 1/f or band-pass filtered noise, but not just mean luminance (i.e., there was no masking from the DC component that corresponds to a channel responsive to a spatial frequency of 0 cyc/deg); longer presentation of the target (corresponding to lower temporal frequencies) produced greater threshold elevation. Conclusions.: Dichoptic masking exhibits similar properties in both subject groups, being low-pass temporally and band-pass spatially, so that masking was greatest at the longest presentation durations and was not greatly affected by mean luminance in the nontested eye.en
dc.description.sponsorshipCanadian Institutes of Health Research || Grant #53346 (RFH).en
dc.identifier.urihttp://dx.doi.org/4098-4104. doi: 10.1167/iovs.14-13969
dc.identifier.urihttp://hdl.handle.net/10012/11326
dc.language.isoenen
dc.publisherAssociation of Research in Vision and Ophthalmologyen
dc.relation.ispartofseriesInvestigative Ophthalmology & Visual Science;55:7en
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEye Movementsen
dc.subjectStrabismusen
dc.subjectAmblyopiaen
dc.subjectNeuro-ophthalmologyen
dc.titleTime Course of Dichoptic Masking in Normals and Suppression in Amblyopesen
dc.typeArticleen
dcterms.bibliographicCitationJiawei Zhou, Suzanne McNeill, Raiju J. Babu, Daniel H. Baker, William R. Bobier, Robert F. Hess; Time Course of Dichoptic Masking in Normals and Suppression in Amblyopes. Invest. Ophthalmol. Vis. Sci. 2014;55(7):4098-4104. doi: 10.1167/iovs.14-13969.en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2School of Optometry and Vision Scienceen
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
i1552-5783-55-7-4098.pdf
Size:
504.76 KB
Format:
Adobe Portable Document Format
Description:
Publisher's version

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.46 KB
Format:
Item-specific license agreed upon to submission
Description: