Development and application of SPME technologies for the rapid sampling and analysis of anthropogenic compounds in the environment

dc.contributor.authorPoole, Justen J.
dc.date.accessioned2017-04-27T13:52:29Z
dc.date.available2017-04-27T13:52:29Z
dc.date.issued2017-04-27
dc.date.submitted2017-04-19
dc.description.abstractDue to the wide spread use of pharmaceuticals in both human and animal populations, the contamination of surface waters resulting from the outflow of waste water treatment facilities is of growing concern. Conventional methods used for the determination of these compounds often require extensive sample preparation in order to achieve appropriate limits of detection and quantitation. As a result, analytical methods which utilize these procedures are limited in their throughput capacity, while also generating large volumes of solvent waste. Coated blade spray (CBS) is a solid phase microextraction (SPME) technique which enables the direct to mass spectrometry analysis of extracted compounds with the application of limited organic solvent in order to desorb analyte and perform electrospray ionization. Demonstrated herein is the application of CBS for the concomitant MS/MS analysis of 12 pharmaceuticals in environmental waters which was able to demonstrate LODs for all compounds at concentrations of less than 50 ng/L while employing a 30 second analysis time. As select pharmaceuticals are susceptible to bioaccumulation, the analysis of fish tissue as a marker of environmental pollution is also an area of interest. For this reason a device was developed, the SPME needle, which is able to perform rapid tissue analysis without the need for a protective sheathing needle or house, simplifying the sampling process. The device was further validated to be reproducible and not effected by puncture through protective tissue. Finally, the device was incorporated into a projectile which was validated to enable rapid one handed SPME sampler administration in a matter of seconds in an on-site proof of concept.en
dc.identifier.urihttp://hdl.handle.net/10012/11766
dc.language.isoenen
dc.pendingfalse
dc.publisherUniversity of Waterlooen
dc.subjectSPMEen
dc.subjectrapid analysisen
dc.subjectdirect to MSen
dc.subjectrecessed sorbenten
dc.titleDevelopment and application of SPME technologies for the rapid sampling and analysis of anthropogenic compounds in the environmenten
dc.typeMaster Thesisen
uws-etd.degreeMaster of Scienceen
uws-etd.degree.departmentChemistryen
uws-etd.degree.disciplineChemistryen
uws-etd.degree.grantorUniversity of Waterlooen
uws.contributor.advisorPawliszyn, Janusz
uws.contributor.affiliation1Faculty of Scienceen
uws.peerReviewStatusUnrevieweden
uws.published.cityWaterlooen
uws.published.countryCanadaen
uws.published.provinceOntarioen
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Poole_Justen.pdf
Size:
3.24 MB
Format:
Adobe Portable Document Format
Description:
pdf of thesis, corrected

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6.17 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections