UWSpace staff members will be away from May 5th to 9th, 2025. We will not be responding to emails during this time. If there are any urgent issues, please contact GSPA at gsrecord@uwaterloo.ca. If any login or authentication issues arise during this time, please wait until UWSpace Staff members return on May 12th for support.
 

On the three charge regimes of bipolar charge conditioners

dc.contributor.authorNishida, Robert, T.
dc.contributor.authorJohnson, Tyler, J.
dc.contributor.authorOlfert, Jason, S.
dc.date.accessioned2025-04-04T14:33:39Z
dc.date.available2025-04-04T14:33:39Z
dc.date.issued2025-03-12
dc.descriptionThis is an Accepted Manuscript of an article published by Taylor & Francis in Aerosol Science and Technology on 12 March 2025, available online: https://doi.org/10.1080/02786826.2025.2461161.
dc.description.abstractMany aerosol instruments utilize bipolar charge conditioners (neutralizers), including scanning mobility particle sizers (SMPS). The charge distribution from a bipolar charge conditioner must be known to calculate size distributions from SMPS scans. Therefore, a reproducible and known “steady-state” charge distribution is desired to improve measurement accuracy. In this work, we show that although a steady-state charge develops within a common Kr-85 bipolar charge conditioner (TSI 3077A), gaseous ions are readily convected into tubing downstream of the charge conditioner, causing significant deviation from steady-state in less than a second. The “downstream ions” are predominantly positive since negative ions are more readily lost to tubing walls due to their higher diffusivity. Others have previously studied this potential effect, but there is disagreement among them. This study resolves the disagreements, and to the authors’ knowledge, we are the first to: quantify the surprising significance of this effect (mean charge at 239 nm changes by up to a factor of 4); show it occurs rapidly (milliseconds); and demonstrate that a true steady-state distribution is more asymmetric than classical theory (mean charge at 239 nm is >3⁢x higher in magnitude). Interaction time of the particles with the remaining free ions downstream of the charge conditioner is shown to be the main consideration for this effect, as demonstrated by varying flow rate, tube length and tube diameter and achieving similar charging results as a function of this time. We perform advanced numerical modeling of charging, convection and diffusion of particles and ions, and show good quantitative agreement with experimental data. These results are further supported by similar charging results measured from a bipolar charge conditioner that has a different internal geometry and ion source than the 3077A charger. To increase consideration of this critical charging effect and enhance understanding of bipolar charging in general, we thereby quantify three distinct regimes of bipolar charging, namely: the (1) charging regime (i.e., as charge develops from its initial to steady-state), (2) steady-state regime, and (3) discharging regime (i.e., effect of “downstream ions”). These three regimes of bipolar charging have wide implications for designing instrumentation, interpreting measurements and validating charging models with the aim of improving accuracy in aerosol instruments such as the SMPS
dc.description.sponsorshipTyler Johnson acknowledges and appreciates the significant support of the Postdoctoral Fellowship from Natural Sciences and Engineering Research Council of Canada (NSERC). Robert Nishida and Jason Olfert received funding support from Transport Canada.
dc.identifier.urihttps://doi.org/10.1080/02786826.2025.2461161
dc.identifier.urihttps://hdl.handle.net/10012/21564
dc.language.isoen
dc.publisherTaylor & Francis
dc.relation.ispartofseriesAerosol Science and Technology; 59(5)
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.titleOn the three charge regimes of bipolar charge conditioners
dc.typeArticle
dcterms.bibliographicCitationNishida, R. T., Johnson, T. J., & Olfert, J. S. (2025). On the three charge regimes of bipolar charge conditioners. Aerosol Science and Technology, 59(5), 499–520. https://doi.org/10.1080/02786826.2025.2461161
uws.contributor.affiliation1Faculty of Engineering
uws.contributor.affiliation2Mechanical and Mechatronics Engineering
uws.peerReviewStatusReviewed
uws.scholarLevelFaculty
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Final_Main.pdf
Size:
757.19 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: