UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

A Device for Measuring Groundwater Velocity in the Capillary Fringe

dc.contributor.authorBerg, Steven James
dc.date.accessioned2007-05-22T13:19:57Z
dc.date.available2007-05-22T13:19:57Z
dc.date.issued2007-05-22T13:19:57Z
dc.date.submitted2007-05-09
dc.description.abstractGroundwater flow in the capillary fringe is rarely measured during hydrogeological studies because of the difficulties associated with investigating this region. Previous research using a point velocity probe (PVP) to investigate groundwater velocity below the water table suggested that the PVP may also be capable of measuring groundwater velocity within the capillary fringe. The earlier PVP was redesigned for this study to allow for groundwater velocity data to be collected remotely. Using this system, groundwater velocity in the capillary fringe was investigated under field and laboratory conditions. Field experiments to investigate horizontal flow in the capillary fringe were conducted either by collecting vertical velocity profiles across the water table, or by holding the probe stationary and allowing seasonal recharge to move the capillary fringe and water table past the probe. Laboratory experiments were conducted in a controlled flow tank that simulated regions of an aquifer up to 85 cm above the water table. The redesigned PVP performed well as a remote system and provided velocity measurements up to 12 cm above the water table under field conditions. These values were consistent with those measured below the water table. In the laboratory, under conditions of drainage, groundwater velocity measurements in the capillary fringe consistent with values below the water table were measured up to 44 cm above the water table. The ability to measure horizontal flow of groundwater in the capillary fringe may open up new avenues for research in the study of contaminant transport in phreatic aquifers.en
dc.format.extent2772755 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/10012/3061
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.subjectgroundwater velocityen
dc.subjectcapillary fringeen
dc.subject.programEarth Sciencesen
dc.titleA Device for Measuring Groundwater Velocity in the Capillary Fringeen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Scienceen
uws-etd.degree.departmentEarth Sciencesen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Thesis_Final_Draft.pdf
Size:
2.64 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
247 B
Format:
Item-specific license agreed upon to submission
Description: