UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

The Performance of Rainscreen Walls in Coastal British Columbia

dc.comment.hiddenPlease note that electronic thesis has been formatted for double sided printing. i.e. both sides of pages are numbered, but backside of some pages ie title page or new sections are blank for printing purposes. This is intentional, please do not reject on this premise. Odd pages face front, even are backside.en
dc.contributor.authorFinch, Graham
dc.date.accessioned2007-09-11T21:32:33Z
dc.date.available2007-09-11T21:32:33Z
dc.date.issued2007-09-11T21:32:33Z
dc.date.submitted2007
dc.description.abstractThis thesis examines the widespread moisture problems which emerged over the past twenty years in buildings throughout coastal British Columbia, commonly known as ‘leaky condos’. A literature review of building physics and a historical review of wood-frame construction in North America provide background for this review. The purpose of this work is to report and interpret the performance of rainscreen walls in the coastal climate of Vancouver BC, based on extensive field data from five local buildings constructed or rehabilitated with rainscreen wall assemblies. Hygrothermal data was collected within exterior walls, and corresponding environmental data was recorded for each building. Driving rain loads at the five buildings across the city are calculated and compared to Vancouver airport data. Site factors are shown to have a significant impact on driving rain load, wind speed and direction. The WUFI 4.1 hygrothermal model was compared with the field data collected and found to be accurate at predicting past performance. Applying this validated model to each wall assembly, further simulations were performed to determine the impact of boundary conditions and assembly details on wall performance. Field measurements and modeling show that ventilated and drained claddings (i.e. rainscreen) reduce the sensitivity of wood frame buildings to moisture damage. Ventilation of the cladding is shown to be particularly important and natural buoyancy forces (from temperature and humidity differences between cavity and exterior) are usually sufficient to provide good drying. Exterior insulation is shown to further improve rainscreen wall performance by increasing the drying potential of the sheathing to both the exterior and interior. Additional work performed included material testing of fiberglass-faced gypsum sheathing and air-leakage testing of individual suites in the monitored buildings. Elevated interior humidity, resulting from inadequate ventilation, is shown to be exacerbated by inter-zonal air-flow in multi-unit residential buildings.en
dc.identifier.urihttp://hdl.handle.net/10012/3223
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.subjectBuildingsen
dc.subjectBuilding Scienceen
dc.subjectRainscreen Wallsen
dc.subjectBuilding Engineeringen
dc.subjectHygrothermal Modelingen
dc.subjectVancouveren
dc.subjectVentilated Claddingsen
dc.subjectLeaky Condosen
dc.subject.programCivil Engineeringen
dc.titleThe Performance of Rainscreen Walls in Coastal British Columbiaen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentCivil and Environmental Engineeringen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
07-09-10_-_Graham_Finch_MASc_-_Final_-_submit.pdf
Size:
219.48 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
248 B
Format:
Item-specific license agreed upon to submission
Description: