Multilayer Energy Discriminating Detector for Medical X-ray Imaging Applications

dc.comment.hiddenI wish to delay web access/display for four months from the date of submission due to a pending publication.en
dc.contributor.authorAllec, Nicholas
dc.date.accessioned2012-12-04T20:50:42Z
dc.date.available2012-12-04T20:50:42Z
dc.date.issued2012-12-04T20:50:42Z
dc.date.submitted2012-11-14
dc.description.abstractContrast-enhanced mammography (CEM) relies on visualizing the growth of new blood vessels (i.e. tumor angiogenesis) to provide sufficient materials for cell proliferation during the development of cancer. Since cancers will accumulate an injected contrast agent more than other tissues, it is possible to use one of several methods to enhance the area of lesions in the x-ray image and remove the contrast of normal tissue. Large area flat panel detectors may be used for CEM wherein the subtraction of two acquired images is used to create the resulting enhanced image. There exist several methods to acquire the images to be subtracted, which include temporal subtraction (pre- and post-contrast images) and dual-energy subtraction (low- and high-energy images), however these methods suffer from artifacts due to patient motion between image acquisitions. In this research the use of a multilayer flat panel detector is examined for CEM that is designed to acquire both (low- and high-energy) images simultaneously, thus avoiding motion artifacts in the resulting subtracted image. For comparison, a dual-energy technique prone to motion artifacts that uses a single-layer detector is also investigated. Both detectors are evaluated and optimized using amorphous selenium as the x-ray to charge conversion material, however the theoretical analysis could be extended to other conversion materials. Experimental results of single pixel prototypes of both multilayer and single-layer detectors are also discussed and compared to theoretical results. For a more comprehensive analysis, the motion artifacts present in dual-exposure techniques are modeled and the performance degradation due to motion artifacts is estimated. The effects of noise reduction techniques are also evaluated to determine potential image quality improvements in CEM images.en
dc.identifier.urihttp://hdl.handle.net/10012/7137
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.subjectX-ray detectorsen
dc.subjectDual-energy imagingen
dc.subjectContrast-enhanced mammographyen
dc.subjectAmorphous seleniumen
dc.subjectMotion artifactsen
dc.subjectNoise reduction techniquesen
dc.subject.programElectrical and Computer Engineeringen
dc.titleMultilayer Energy Discriminating Detector for Medical X-ray Imaging Applicationsen
dc.typeDoctoral Thesisen
uws-etd.degreeDoctor of Philosophyen
uws-etd.degree.departmentElectrical and Computer Engineeringen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Allec_Nicholas.pdf
Size:
4.78 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
249 B
Format:
Item-specific license agreed upon to submission
Description: