Stereocoherence thresholds as a measure of global stereopsis

dc.contributor.authorUnnisa Begum, Viquar
dc.date.accessioned2017-06-14T16:06:00Z
dc.date.available2017-06-14T16:06:00Z
dc.date.issued2017-06-14
dc.date.submitted2017-05-03
dc.description.abstractPurpose: The purpose of this study was to develop a robust and reliable clinical test of stereopsis that is complementary to the conventional disparity threshold tests. Methods: Random dot stereograms containing disparity-defined gratings were displayed on a ViewPixx® monitor using LCD shutter glasses. Participants discriminated grating orientation. Form coherence was degraded by assigning random disparities to a variable proportion of dots. The threshold proportion of signal dots required for form discrimination is called the stereocoherence threshold (stereoCT). We explored the various stimulus parameters that can affect stereoCT. StereoCT were also measured for a variety of simulated abnormal binocular vision conditions and in patients with amblyopia. Results: StereoCT was lowest (most sensitive) for a stimulus with a spatial frequency of 1cpd ,a 5.5 arc min dot size, 183 dots/deg2 dot density and a disparity amplitude of 108 arc sec. StereoCT showed higher sensitivity and reduced variability relative to stereothresholds obtained on conventional disparity thresholds under various simulated abnormal vision conditions (interocular luminance and contrast differences, unilateral blur, and unilateral Bangerter filters). In patients with amblyopia, stereoCT improved with contrast reduction in the fellow eye relative to the amblyopic eye. Conclusions: StereoCT testing targets the second stage of stereoscopic processing ‘global stereopsis where the local matches of stereoscopic images between two eyes are unified into a global perception of depth. Therefore, stereoCT may provide a useful measure of higher-level stereoscopic vision that is complementary to current tests, which rely on disparity thresholds.en
dc.identifier.urihttp://hdl.handle.net/10012/12009
dc.language.isoenen
dc.pendingfalse
dc.publisherUniversity of Waterlooen
dc.subjectBinocular visionen
dc.subjectLocal and global stereopsisen
dc.subjectAmblyopiaen
dc.titleStereocoherence thresholds as a measure of global stereopsisen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Scienceen
uws-etd.degree.departmentSchool of Optometry and Vision Scienceen
uws-etd.degree.disciplineVision Scienceen
uws-etd.degree.grantorUniversity of Waterlooen
uws.contributor.advisorThompson, Benjamin
uws.contributor.advisorMcCulloch, Daphne
uws.contributor.affiliation1Faculty of Scienceen
uws.peerReviewStatusUnrevieweden
uws.published.cityWaterlooen
uws.published.countryCanadaen
uws.published.provinceOntarioen
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Unnisa_Begum_Viquar.pdf
Size:
1.67 MB
Format:
Adobe Portable Document Format
Description:
Thesis dissertation

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6.17 KB
Format:
Item-specific license agreed upon to submission
Description: