Evaluation and Quantification of Engineered Flocs and Drinking Water Treatability

dc.contributor.authorArnold, Adam
dc.date.accessioned2008-08-28T12:44:26Z
dc.date.available2008-08-28T12:44:26Z
dc.date.issued2008-08-28T12:44:26Z
dc.date.submitted2008
dc.description.abstractJar tests are performed to simulate full-scale pre-treatment and particle removal processes. Operators typically conduct them in an effort to attempt alternative treatment doses and strategies without altering the performance of the full-scale drinking water treatment plant. However, information obtained from these tests must be evaluated judiciously, as they currently focus on reduction of specific water quality parameters (i.e., ultraviolet absorption at 254 nm (UV254) and turbidity), and measuring and understanding the significance of coagulant dose on floc size. Consideration of aggregate structure has been less explored due mainly to a lack of appropriate theories to describe the complex random floc structure. Improving the predictive capacity of bench-scale protocols commonly used for optimizing conventional chemical pre-treatment in full-scale drinking water treatment plants is required. Results from settling tests indicated that the production of larger and more settleable flocs could not be described by floc settling velocities and floc sizes. Settling velocities were not directly related to either UV254 or turbidity reductions. Results of the floc characterization tests indicated that measured values of UV254 and turbidity of the supernatant were generally inversely proportional to aggregate D90; that is, the residual UV254 and/or turbidity decreased as the value of D90 increased, which may have been indicative of flocculent settling. No direct relationship could be discerned between fractal dimension D1 (i.e., floc shape) and the UV254 and turbidity of the supernatant; however, the turbidity after flocculation and a period of settling appeared to be inversely proportional to fractal dimension D2 (i.e., porosity). Overall, the results of the experiments have demonstrated that grain size distributions and fractal dimensions might be used to assess and/or predict pre-treatment and/or particle removal performance. Specifically, the relationship between D90 values calculated from samples of flocculated water prior to settling and UV254 and turbidity values of that water after a period of settling may be a simple tool that can be utilized to describe and potentially better predict flocculent settling performance. At present, this appears to be the first such tool of its kind that has been reported.en
dc.identifier.urihttp://hdl.handle.net/10012/3909
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.subjectFractal Dimensionen
dc.subjectJar Testen
dc.subjectCoagulationen
dc.subjectFlocculationen
dc.subject.programCivil Engineeringen
dc.titleEvaluation and Quantification of Engineered Flocs and Drinking Water Treatabilityen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentCivil and Environmental Engineeringen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AArnold_UW_MASc_Thesis.pdf
Size:
10.23 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
257 B
Format:
Item-specific license agreed upon to submission
Description: