Developing a Colorimetric, Magnetically Separable Sensor for the Capture and Detection of Biomarkers

dc.comment.hiddenChapter 2 (Literature Review) has been published in Expert Review of Molecular Diagnostics in 2011, volume 11, issue 5, pages 487-96. A statement indicating this, along with the authors (my name and my supervisor), appears at the beginning of the chapter. The publisher has provided written permission, in the form of a copyright permission form, to allow the use of the manuscript text to appear in the thesis, which I am happy to provide if required.en
dc.contributor.authorChan, Terence
dc.date.accessioned2012-08-30T20:01:35Z
dc.date.available2012-08-30T20:01:35Z
dc.date.issued2012-08-30T20:01:35Z
dc.date.submitted2012-08-29
dc.description.abstractPoint-of-care testing (POCT) devices have received increasing attention because of their potential to address the urgent need for quick and accurate diagnostic tools, especially in areas of personal care and clinical medicine. They offer several benefits over current diagnostic systems, including rapid diagnostic results in comparison to microbial cultures, simple interpretation of results, portability, and requiring no specialised laboratory equipment or technical training to operate. These are essential for diagnosing critical illnesses, such as sepsis, in areas of poor healthcare infrastructure. Sepsis, an innate physiological response to infection, is a growing problem worldwide with high associated costs and mortality rates, and affects a wide range of patients including neonates, infants, the elderly, and immunocompromised individuals. A literature review of the biomarkers of sepsis and the currently available diagnostic systems indicates the need for a biosensor capable of meeting the requirements of designing POCT systems and achieving detection of low concentrations of biomarkers. To meet these demands, two significant contributions to developing POCT platforms have been achieved and described in this thesis, including: 1) development of a colorimetric, magnetically separable biosensor that can be easily fabricated and demonstrates an easily identifiable colour response upon analyte detection, as well as the ability to capture and detection target biomarkers at low concentrations from complex solutions; and 2) tuning of the biosensor’s colorimetric response to achieve low detection limits, as well as demonstration of the versatility of the biosensor for sensing different target analytes. The developed biosensor in this work combines colour responsive polydiacetylenes and superparamagnetic iron oxide for the first time to achieve a biosensor capable of meeting these demands. The sensors exhibit identifiable colour responses to biomolecule detection, capture of a target analyte from complex solutions, sensing of different target analytes, a lower detection limit of 0.01 mg/mL, and rapid separation from solution with a common magnet. This work has been a significant demonstration of the capabilities of this biosensor as a new platform for POCT systems to diagnosis sepsis, and potentially other sensing applications.en
dc.identifier.urihttp://hdl.handle.net/10012/6945
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.subjectpoint-of-care testingen
dc.subjectsepsisen
dc.subjectcolorimetricen
dc.subjectmagnetic separationen
dc.subjectpolydiacetyleneen
dc.subjectbiosensoren
dc.subject.programChemical Engineeringen
dc.titleDeveloping a Colorimetric, Magnetically Separable Sensor for the Capture and Detection of Biomarkersen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentChemical Engineeringen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Chan_Terence.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
248 B
Format:
Item-specific license agreed upon to submission
Description: