UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Development and Commissioning of a Large-scale Rotatable Guarded Hot Plate Apparatus

dc.contributor.authorSimonji, Joseph Paul
dc.date.accessioned2016-10-26T15:16:34Z
dc.date.available2016-10-26T15:16:34Z
dc.date.issued2016-10-26
dc.date.submitted2016-09-23
dc.description.abstractA large-scale guarded hot plate apparatus was designed and constructed for measurement of the thermal conductivity of thick insulation specimens and specimens containing layers and/or complex 3D heat flows (i.e. thermal bridges). The apparatus is capable of accepting specimens measuring 4’ (1219mm) by 4’ (1219mm) and up to 16” (406mm) thick with good accuracy in measurement. Computer models were developed to estimate heat flow errors important for determining the characteristics and limitations of the apparatus. Other sources of error in measurement were also evaluated. Once constructed, the apparatus was validated against a heat flow meter calibrated to better than 1% using a US National Institute of Standards and Technology (NIST) traceable calibration sample. Good agreement was shown between the heat flow meter and the guarded hot plate; <1% deviation in thermal conductivity measurement was observed for a 3” (76mm) thick stonewool specimen and <3.5% deviation in thermal conductivity measurement was observed for a 9” (229mm) thick stonewool specimen. The capability of the guarded hot plate to measure layered specimens with thermal bridges was demonstrated through the measurement of three specimens resembling typical wall assemblies. Measurements from the apparatus were compared against results from computer models and good agreement was found. Errors normally associated with the measurement of non-homogenous specimens in guarded hot plates were not found to be an issue.en
dc.identifier.urihttp://hdl.handle.net/10012/11030
dc.language.isoenen
dc.pendingfalse
dc.publisherUniversity of Waterlooen
dc.subjectthermal bridgeen
dc.subjectthermal conductivityen
dc.subjectguarded hot plateen
dc.titleDevelopment and Commissioning of a Large-scale Rotatable Guarded Hot Plate Apparatusen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentCivil and Environmental Engineeringen
uws-etd.degree.disciplineCivil Engineeringen
uws-etd.degree.grantorUniversity of Waterlooen
uws.contributor.advisorStraube, John
uws.contributor.affiliation1Faculty of Engineeringen
uws.peerReviewStatusUnrevieweden
uws.published.cityWaterlooen
uws.published.countryCanadaen
uws.published.provinceOntarioen
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Simonji_Joseph.pdf
Size:
13.18 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6.17 KB
Format:
Item-specific license agreed upon to submission
Description: