A High-Resolution CMOS Single-Photon-Counting Spectrographic X-Ray Imager

dc.contributor.authorWright, Michael
dc.date.accessioned2023-09-01T13:18:52Z
dc.date.issued2023-09-01
dc.date.submitted2023-08-27
dc.description.abstractDigital X-ray imagers for clinical mammography and computed tomography (CT) have been recently taking advantage of the noise-rejection properties of single-photon-counting (SPC) architectures. However, conventional SPC imagers are limited in spatial and energy resolution due to the substantial circuit area required to accommodate signal processing and digitization components in each pixel. To enable higher spatial resolution using smaller pixels, while simultaneously increasing energy resolution for multi-spectral imaging, new circuit architectures are required for SPC X-ray imagers. This thesis presents the design and experimental characterization of the first comple- mentary metal-oxide-semiconductor (CMOS) SPC X-ray imager readout integrated circuit (ROIC) to use frequency-division-multiplexed (FDM) readout for improved spatial and energy resolution. FDM readout allows the pixels in our ROIC to share analog-to-digital converter (ADC) resources, so that fewer components are integrated in each pixel. This enables us to shrink the pixel area, improving spatial resolution. Shared ADCs also have higher resolution than those in conventional implementations, enabling higher overall en- ergy resolution. Our proposed ROIC, designed in a 180-nm CMOS technology, includes an 8 × 16 pixel array and 16 ADCs. To achieve high spatial resolution and sufficient count rate for mam- mography and CT, we design our pixels with an area of only 35 × 35 μm^2, approximately 50% smaller than commercial SPC imagers. Our ROIC uses FDM readout to multiplex banks of eight pixels into a shared 8-bit 160-MHz-sample-rate pipelined ADC, enabling full digitization of pixel analog outputs. We achieve six bins of energy resolution, which exceeds the resolution of recently-reported conventional SPC imagers that use larger-area pixels. Our ROIC also has a measured equivalent-noise charge (ENC) of 101 e−rms, which is comparable to conventional imagers, and a maximum count-rate of 10^8 photons/mm^2/s, suitable for mammography and CT.en
dc.identifier.urihttp://hdl.handle.net/10012/19826
dc.language.isoenen
dc.pendingfalse
dc.publisherUniversity of Waterlooen
dc.subjectsingle photon countingen
dc.subjectanalog circuit designen
dc.subjectx-ray imagingen
dc.titleA High-Resolution CMOS Single-Photon-Counting Spectrographic X-Ray Imageren
dc.typeMaster Thesisen
uws-etd.degreeMaster of Applied Scienceen
uws-etd.degree.departmentElectrical and Computer Engineeringen
uws-etd.degree.disciplineElectrical and Computer Engineeringen
uws-etd.degree.grantorUniversity of Waterlooen
uws-etd.embargo2025-08-31T13:18:52Z
uws-etd.embargo.terms2 yearsen
uws.contributor.advisorLevine, Peter
uws.contributor.advisorCamlica, Ahmet
uws.contributor.affiliation1Faculty of Engineeringen
uws.peerReviewStatusUnrevieweden
uws.published.cityWaterlooen
uws.published.countryCanadaen
uws.published.provinceOntarioen
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6.4 KB
Format:
Item-specific license agreed upon to submission
Description: