UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Effect of H2 Pressure on Hydrogen Absorption and Granular Iron Corrosion Rates

dc.contributor.authorTaylor, Emily
dc.date.accessioned2014-01-08T15:12:49Z
dc.date.available2014-01-08T15:12:49Z
dc.date.issued2014-01-08
dc.date.submitted2013
dc.description.abstractHydrogen gas production occurs in permeable reactive iron barriers (PRBs) due to the anaerobic corrosion of granular iron. Once produced, this hydrogen gas can have detrimental physical effects on PRB performance. Corrosion-produced hydrogen may accumulate in pore spaces within the PRB, thereby reducing the porosity and permeability. It may also escape the PRB system, representing a lost electron resource that may otherwise be used in reductive remediation reactions. In addition to these physical effects of hydrogen on PRB performance, chemical interactions between hydrogen and iron also occur. Hydrogen may become absorbed by the iron and stored as an electron resource within lattice imperfections. It may also interact with iron surfaces to influence the corrosion rate of the iron. These chemical interactions between hydrogen and iron may impact the reactivity of the iron granules and therefore affect PRB performance. Currently, the chemical effects of hydrogen on PRB performance remain largely unexplored. In this study, the effect of hydrogen on iron reactivity was investigated by considering hydrogen absorption into iron and hydrogen induced changes to iron corrosion rates. Hydrogen absorption by iron creates a stored electron resource within the iron granules. Release of this stored hydrogen from trapping sites represents an additional electron resource that may be used in contaminant degradation reactions. Therefore, improved hydrogen absorption may contribute to increased iron reactivity. Hydrogen absorption by granular irons has been largely unexplored in PRB performance investigations and the effect of hydrogen absorption on contaminant remediation remains unknown. In this study, an investigation of the factors governing hydrogen absorption by three granular irons, H2Omet56, H2Omet58 and H2Omet86 was conducted. The results demonstrated that rapidly corroding H2Omet86 absorbed hydrogen at a higher rate than the other more slowly corroding irons. The presence of an oxide film on H2Omet56 appeared to improve the proportion of hydrogen absorption compared to the bare irons. Ultrasonic treatment was explored as potential method of release of trapped hydrogen for improved iron reactivity. Ultrasonic treatment appeared to be unsuccessful at releasing stored hydrogen from trapping sites, but further investigations into different ultrasound conditions as well as other methods of hydrogen release could prove useful. Hydrogen gas may also influence iron reactivity by interacting with iron surfaces to alter the corrosion rate of the iron. This may occur by processes such as hydrogen enhanced anodic dissolution, hydrogen induced cracking, enhanced pitting susceptibility and reduction of iron oxides by hydrogen gas. In this study, the effect of hydrogen on iron corrosion rates was assessed by treating two iron materials (H2Omet56 and Connelly) under high pressures of hydrogen for 14 d, then comparing the post-treatment corrosion rates of hydrogen treated irons to the post-treatment corrosion rates of corresponding irons treated under low hydrogen pressures for the same period. The results demonstrated that the post-treatment corrosion rate of high hydrogen treated H2Omet56 iron was lower than the post-treatment corrosion rate of low hydrogen treated H2Omet56 iron. Hydrogen treatment did not appear to affect the post-treatment corrosion rates of Connelly iron. The effect of hydrogen on the corrosion rate of H2Omet56 iron may be a result of hydrogen enhanced anodic dissolution. The presence of a continuous oxide film on Connelly iron appeared to inhibit the effect of hydrogen enhanced anodic dissolution on Connelly iron corrosion rates. The effects of iron oxide reduction by hydrogen and hydrogen induced pitting corrosion were also considered.en
dc.identifier.urihttp://hdl.handle.net/10012/8129
dc.language.isoenen
dc.pendingfalse
dc.publisherUniversity of Waterlooen
dc.subjectgranular ironen
dc.subjecthydrogen gasen
dc.subjectlattice uptakeen
dc.subjectanaerobic corrosionen
dc.subjectPRBsen
dc.subject.programEarth Sciencesen
dc.titleEffect of H2 Pressure on Hydrogen Absorption and Granular Iron Corrosion Ratesen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Scienceen
uws-etd.degree.departmentEarth Sciencesen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Taylor_Emily.pdf
Size:
3.2 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.89 KB
Format:
Item-specific license agreed upon to submission
Description: