Show simple item record

dc.contributor.authorCase, Ryan
dc.date.accessioned2012-08-27 14:17:33 (GMT)
dc.date.available2012-08-27 14:17:33 (GMT)
dc.date.issued2012-08-27T14:17:33Z
dc.date.submitted2012
dc.identifier.urihttp://hdl.handle.net/10012/6885
dc.description.abstractWith the commercial and institutional building sectors using approximately 29% and 34% of all electrical energy consumption in Canada and the United States, respectively, saving electrical energy in commercial and institutional buildings represents an important chal- lenge for both the environment and the energy consumer. Concurrently, a rapid decline in the cost of microprocessing and communication has enabled the profileration of smart me- ters, which allow a customer to monitor energy usage every hour, 15 minutes or even every minute. Algorithmic analysis of this stream of meter readings would allow 1) a building operator to predict the potential cost savings from implemented energy savings measures without engaging the services of an expensive energy expert; and 2) an energy expert to quickly obtain a high-level understanding of a building’s operating parameters without a time-consuming and expensive site visit. This thesis develops an algorithm that takes as input a stream of building meter data and outputs a building’s operating parameters. This output can be used directly by an energy expert to assess a building’s performance; it can also be used as input to other algorithms or systems, such as systems that 1) predict the cost savings from a change in these operating parameters; 2) benchmark a portfolio of building; 3) create baseline models for measurement and verification programs; 4) detect anomalous building behaviour; 5) provide novel data visualization methods; or 6) assess the applicability of demand response programs on a given building. To illustrate this, we show how operating parameters can be used to estimate potential energy savings from energy savings measures and predict building energy consumption. We validate our ap- proach on a range of commercial and institutional buildings in Canada and the United States; our dataset consists of 10 buildings across a variety of geographies and industries and comprises over 21 years of meter data. We use K-fold cross-validation and benchmark our work against a leading black-box prediction algorithm; our model offers comparable prediction accuracy while being far less complex.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectelectrical energyen
dc.subjectcommercial buildingsen
dc.subjectstatisticsen
dc.subjectdata miningen
dc.titleSaving Electrical Energy in Commercial Buildingsen
dc.typeMaster Thesisen
dc.pendingfalseen
dc.subject.programComputer Scienceen
uws-etd.degree.departmentSchool of Computer Scienceen
uws-etd.degreeMaster of Mathematicsen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages