Saving Electrical Energy in Commercial Buildings

dc.contributor.authorCase, Ryan
dc.date.accessioned2012-08-27T14:17:33Z
dc.date.available2012-08-27T14:17:33Z
dc.date.issued2012-08-27T14:17:33Z
dc.date.submitted2012
dc.description.abstractWith the commercial and institutional building sectors using approximately 29% and 34% of all electrical energy consumption in Canada and the United States, respectively, saving electrical energy in commercial and institutional buildings represents an important chal- lenge for both the environment and the energy consumer. Concurrently, a rapid decline in the cost of microprocessing and communication has enabled the profileration of smart me- ters, which allow a customer to monitor energy usage every hour, 15 minutes or even every minute. Algorithmic analysis of this stream of meter readings would allow 1) a building operator to predict the potential cost savings from implemented energy savings measures without engaging the services of an expensive energy expert; and 2) an energy expert to quickly obtain a high-level understanding of a building’s operating parameters without a time-consuming and expensive site visit. This thesis develops an algorithm that takes as input a stream of building meter data and outputs a building’s operating parameters. This output can be used directly by an energy expert to assess a building’s performance; it can also be used as input to other algorithms or systems, such as systems that 1) predict the cost savings from a change in these operating parameters; 2) benchmark a portfolio of building; 3) create baseline models for measurement and verification programs; 4) detect anomalous building behaviour; 5) provide novel data visualization methods; or 6) assess the applicability of demand response programs on a given building. To illustrate this, we show how operating parameters can be used to estimate potential energy savings from energy savings measures and predict building energy consumption. We validate our ap- proach on a range of commercial and institutional buildings in Canada and the United States; our dataset consists of 10 buildings across a variety of geographies and industries and comprises over 21 years of meter data. We use K-fold cross-validation and benchmark our work against a leading black-box prediction algorithm; our model offers comparable prediction accuracy while being far less complex.en
dc.identifier.urihttp://hdl.handle.net/10012/6885
dc.language.isoenen
dc.pendingfalseen
dc.publisherUniversity of Waterlooen
dc.subjectelectrical energyen
dc.subjectcommercial buildingsen
dc.subjectstatisticsen
dc.subjectdata miningen
dc.subject.programComputer Scienceen
dc.titleSaving Electrical Energy in Commercial Buildingsen
dc.typeMaster Thesisen
uws-etd.degreeMaster of Mathematicsen
uws-etd.degree.departmentSchool of Computer Scienceen
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Case_Ryan.pdf
Size:
5.23 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
244 B
Format:
Item-specific license agreed upon to submission
Description: