dc.description.abstractWith the desire for energy conservation and lower costs, the application of pulse-width modulated (PWM) voltage source converter (VSC) drives has grown at an exponential rate. However, due to their high switching frequency and high dv/dt, increased dielectric stresses and thermal stresses are applied to the insulation system of the motors, which may lead to the failure of the insulation. In order to test the performance of the motor insulation under the above complex stress conditions, an IGBT-based pulse voltage generator which can produce high voltage square wave and PWM waveforms has been successfully developed in this research. The generator consists of IGBT switches and other wave shaping components. The special cascade connection circuit design enables the generator to produce the stable high voltage square wave and PWM waveforms. A microcontroller-based trigger signal generator is used to trigger the power electronic switches in the generator. In order to avoid false triggering from electromagnetic interference (EMI), optical fibre cables are used to connect the trigger signal generator to the switches which are located in a high electric potential area. The generator can produce square wave and PWM waveforms with a peak voltage up to 15 kV and with a switching frequency of 600 Hz to 6 kHz. The fundamental frequency of the PWM waveform is 20 Hz to 1200 Hz, the rise time is less than 200 ns, and the pulse width can be varied up to several milliseconds. A 4 kVrms form wound model stator coil was tested under different voltage waveforms: power frequency, exponential decay pulse, square wave, and sinusoidal pulse-width modulated (SPWM) waveform. Infrared images and the maximum temperature rise of the coil under different electrical stresses were recorded. The results show that both the square and SPWM voltage waveforms cause a significantly higher temperature rise than the power frequency and exponential decay pulse voltage waveforms. Since the actual VSCs generate transients similar to those of the square and PWM voltage waveforms, it is recommended that the stator coil insulation be analyzed using PWM voltage waveforms in order to simulate actual conditions.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectinsulation testen
dc.subjectpower electronicen
dc.subjectpulse voltageen
dc.subjectPWM waveformen
dc.titleDesign and Development of IGBT-Based Pulse Voltage Generator for Insulation Testingen
dc.typeMaster Thesisen
dc.pendingtrueen
dc.subject.programElectrical and Computer Engineeringen
dc.description.embargoterms1 yearen
uws-etd.degree.departmentElectrical and Computer Engineeringen
uws-etd.degreeMaster of Applied Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages