UWSpace will be migrating to a new version of its software from July 29th to August 1st. UWSpace will be offline for all UW community members during this time.

Show simple item record

dc.contributor.authorSultana, Papia
dc.date.accessioned2007-09-13 16:30:39 (GMT)
dc.date.available2007-09-13 16:30:39 (GMT)
dc.date.issued2007-09-13T16:30:39Z
dc.date.submitted2007
dc.identifier.urihttp://hdl.handle.net/10012/3231
dc.description.abstractIn recent years, light gauge cold-formed steel members have been used extensively in low and mid- rise residential building construction. In cold-formed steel design there are several applications where built-up box girders are used to resist load induced in a structure when a single section is not sufficient to carry the design load. The cold-formed steel box girders may be subjected to eccentric loading when the web of one of the sections receives the load and transfers it through the connection to another section. There may be an unequal distribution of load in built-up girder assemblies loaded from one side. In the current North American Specification for the Design of Cold-Formed Steel Structural Members (CSA-S136-01, 2001), there is no guideline or design equation to calculate the flexural capacity of this type of section. AISI cold-formed steel framing design guide (2002) has recommended that the moment of resistance and inertia of the built-up section are the simple addition of the component parts, based on deflection compatibility of the two sections. However, this design approximation has not been justified by any experimental or numerical study. Very little information was found in literature about this topic. The objective of this study is the investigation of the flexural behaviour of built-up box girders assembled from cold-formed stud and track sections when subjected to eccentric loading. Finite element analysis is conducted for this purpose, being much more economical than expensive experimental testing. Detailed parametric studies are carried out to identify the factors affecting the flexural capacity of built-up cold-formed steel sections. The parametric results are used to develop a design equation for calculating the flexural capacity of built-up cold-formed steel sections.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectCold-formed steelen
dc.subjectBuilt-up sectionsen
dc.titlePredictions of Flexural Behaviour of Built-Up Cold-Formed Steel Sectionsen
dc.typeMaster Thesisen
dc.pendingfalseen
dc.subject.programCivil Engineeringen
uws-etd.degree.departmentCivil and Environmental Engineeringen
uws-etd.degreeMaster of Applied Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages