PV and HP Disaggregation for Transmission System Applications
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
University of Waterloo
Abstract
Utility customers in Canada and across the globe are installing Photovoltaic (PV) and Heat Pump (HP) systems at the Low Voltage (LV) level of distribution grids. Current projections indicate a continued global increase in the integration of these systems. The responsibility for managing the electric grid at this level primarily falls to Distribution System Operators (DSOs). However, the growing integration of these systems into distribution networks has limited visibility for transmission system operators, as the power output of those low-power systems is not typically monitored. Since the increased presence of PV and HP systems significantly impacts the grid, more detailed information is needed than what is currently provided by existing measurements. Hence, leveraging data to identify the capacity and aggregate signature of PV and HP systems from net-load measurements at the High Voltage (HV)/ Medium Voltage (MV) level in the transmission system is required to address this information gap, which is the focus of the proposed research. The research presented in this thesis first introduces a novel approach for disaggregating PV generation from net-load measurements recorded at the HV level. The proposed technique is applied to actual data from an existing transmission line feeder to identify PV generation from net demand measurements. The methodology incorporates Geographical Information Systems (GIS) for detecting PV panels based on an algorithm that provides an accurate estimate of solar PV capacity. These estimations are validated against actual data from a local utility, showing a close match with the observed results. This information is then used in software tools to simulate PV power generation in the studied region, which is then used to estimate and disaggregate the generated power from net-load data by applying multiple Machine Learning (ML) and Deep Learning (DL) models. The results obtained for the Waterloo region in connection with the Independent Electricity System Operator (IESO) demonstrate that it is feasible to adequately disaggregate in practice PV power generation from transmission feeder net-load measurements with minimal or no additional sensor infrastructure. The second part of this thesis focuses on identifying HP loads at the transmission system level, since the widespread adoption of HPs, particularly as replacements for fossil-based furnaces, raises concerns about potential grid issues at the HV level, where existing infrastructure may be insufficient to manage the increased load. Additionally, the implementation of sub-metering infrastructure to monitor energy consumption specifically for HPs’ LV loads is often expensive and not really available. In this context, understanding the power consumption of HPs is important, considering the frequency of their on-off transitions that significantly influence their demand patterns. However, the power demand of HPs in real-world operations has not been thoroughly characterized, and effective methods for detecting aggregated patterns are still underdeveloped. Thus, the presented research investigates how single smart meter data can be utilized to extract key indicators of HP demand profiles under varying outdoor temperature conditions. The proposed framework generates synthetic HP load consumption profiles and aggregates them at the transmission level. These aggregated profiles are then used to disaggregate HP loads from total power measurements using simulation models, data-driven approaches, and supervised ML and DL techniques for net load disaggregation. The results obtained using actual data provided by IESO from an HV/MV substation in Milton, Ontario, Canada, indicate that the proposed framework successfully captures temperature-dependent HP behavior and provides a reasonable approximation of aggregated real-world HP loads at the transmission system level, highlighting the practical relevance of the proposed technique for the IESO.