dc.description.abstractRadiation causes soft errors in memory devices, and a variety of research has been focused on techniques to reduce these soft errors. In this thesis, instead of mitigating soft errors, we present an SRAM based dosimeter which uses the soft error susceptible nature of SRAMs as a means of measuring radiation fluence. This cost effective, real-time dosimeter can be used to calibrate and characterize neutron and proton beams with wide-range spectra. The design of the SRAM dosimeter includes both hardware and software. An array of thirty 16-Mbit off-the-shelf 65 nm SRAMs are used as sensors directly exposed to radiation. An FPGA is used as a processor to analyze the sensor data and communicate with a PC. Finally, a graphical user interface is provided for interacting with the dosimeter. The dosimeter device has been validated at the TRIUMF proton and neutron irradiation facility, and has been used by the facility to carry out various calibration and measurement activities such as proton and neutron beam characterization, beam profile measurements, collimator design and shielding effects measurements.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectdosimeteren
dc.subjectsramen
dc.subjectprotonen
dc.subjectneutronen
dc.subjectfpgaen
dc.subject.lcshDosimetersen
dc.subject.lcshStatic random access memoryen
dc.subject.lcshProtonsen
dc.subject.lcshNeutronsen
dc.subject.lcshField programmable gate arraysen
dc.titleDesign of SRAM Based Dosimetry Used for Neutron and Proton Detectionen
dc.typeMaster Thesisen
dc.pendingfalse
uws-etd.degree.departmentElectrical and Computer Engineeringen
uws-etd.degree.disciplineElectrical and Computer Engineeringen
uws-etd.degree.grantorUniversity of Waterlooen
uws-etd.degreeMaster of Applied Scienceen
uws.contributor.advisorSachdev, Manoj
uws.contributor.advisorWright, Derek
uws.contributor.affiliation1Faculty of Engineeringen
uws.published.cityWaterlooen
uws.published.countryCanadaen
uws.published.provinceOntarioen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages