Show simple item record

dc.contributor.authorBirjandi, Afsoon Pajand
dc.contributor.authorBojko, Barbara
dc.contributor.authorNing, Zhibin
dc.contributor.authorFigeys, Daniel
dc.contributor.authorPawliszyn, Janusz
dc.date.accessioned2017-09-11 15:50:48 (GMT)
dc.date.available2017-09-11 15:50:48 (GMT)
dc.date.issued2017-02-01
dc.identifier.urihttp://dx.doi.org/10.1016/j.jchromb.2016.09.034
dc.identifier.urihttp://hdl.handle.net/10012/12361
dc.descriptionThe final publication is available at Elsevier via http://dx.doi.org/10.1016/j.jchromb.2016.09.034 © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractA new SPME method for untargeted lipidomic study of cell line cultures was proposed for the first time. In this study the feasibility to monitor changes in lipid profile after external stimuli was demonstrated and compared to the conventional Bligh & Dyer method. The human hepatocellular carcinoma (HCC) cell line was used as a model. The obtained results provided a list of up-regulated and down-regulated lipids through a comparison between control (non-stimulated) cells versus the group of cells treated with polyunsaturated fatty acid (20:5). Use of the SPME technique yielded a list of 77 lipid species whose concentrations were recognized to be significantly different between control and treated cells, from which 63 lipids were up-regulated in treated cells. In general, the list was comparable to the peer list obtained by the Bligh & Dyer method. However, more diversity of lipid classes and subclasses such as LPC, sphingomyelins, ceramides, and prenol lipids were observed with the application of the SPME method. Method precision for the SPME approach was within the acceptable analytical range (5-18% RSD) for all detected lipids, which was advantageous over solvent extraction applied. The evaluation of ionization efficiency indicated no matrix effect for the SPME technique, while Bligh" & Dyer presented significant ionization suppression for low abundant species such as LysoPC, PG, ceramides, and sphingomyelins, and ionization enhancement for high abundant phospholipids such as PE.en
dc.description.sponsorshipNatural Sciences and Engineering Research Council of Canada (NSERC)en
dc.language.isoenen
dc.publisherElsevieren
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectLipidomicsen
dc.subjectCell line studyen
dc.subjectSolid phase microextractionen
dc.subjectAutomationen
dc.titleHigh throughput solid phase microextraction: A new alternative for analysis of cellular lipidome?en
dc.typeArticleen
dcterms.bibliographicCitationBirjandi, A. P., Bojko, B., Ning, Z., Figeys, D., & Pawliszyn, J. (2017). High throughput solid phase microextraction: A new alternative for analysis of cellular lipidome? Journal of Chromatography B, 1043, 12–19. https://doi.org/10.1016/j.jchromb.2016.09.034en
uws.contributor.affiliation1Faculty of Scienceen
uws.contributor.affiliation2Chemistryen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International

UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages