Show simple item record

dc.contributor.authorYeow, John
dc.contributor.authorOrchard, Jeff
dc.contributor.authorKim, Hwa Young
dc.date.accessioned2017-02-10 20:33:29 (GMT)
dc.date.available2017-02-10 20:33:29 (GMT)
dc.date.issued2012-06-04
dc.identifier.urihttp://dx.doi.org/10.2174/1874347101206010001
dc.identifier.urihttp://hdl.handle.net/10012/11309
dc.description.abstractThe very hot and power-hungry x-ray filaments in today's computed tomography (CT) scanners constrain their design to be big and stationary. What if we built a CT scanner that could be deployed at the scene of a car accident to acquire tomographic images before moving the victim? Recent developments in nanotechnology have shown that carbon nanotubes can produce x-rays at room temperature, and with relatively low power needs. We propose a design for a portable and flexible CT scanner made up of an addressable array of tiny x-ray emitters and detectors. In this paper, we outline a basic design, propose a strategy for reconstruction, and demonstrate the feasibility of reconstruction using experiments on a software simulation of the flexible scanner. These simulations show that reconstruction quality is stable over a wide range of scanner geometries, while progressively larger errors in the scanner geometry induce progressively larger errors. We also raise a number of issues that still need to be overcome to build such a scanner.en
dc.description.sponsorshipThis work was supported by funding from the Natural Sciences and Engineering Research Council of Canada (NSERC), the Canada Foundation for Innovation, and the Ontario Innovation Trust.en
dc.language.isoenen
dc.publisherBentham Openen
dc.relation.ispartofseriesThe Open Medical Imaging Journal;6en
dc.rightsAttribution-NonCommercial 3.0 Unported*
dc.rights.urihttps://creativecommons.org/licenses/by-nc/3.0/*
dc.subjectComputed tomographyen
dc.subjectReconstructionen
dc.subjectNanotechnologyen
dc.subjectPETen
dc.titlePlausibility of Image Reconstruction Using a Proposed Flexible and Portable CT Scanneren
dc.typeArticleen
dcterms.bibliographicCitationKim, H.W., Orchard, J., Yeow, J.T.W. (2012). Plausibility of image reconstruction using a proposed flexible and portable CT scanner. The Open Medical Imaging Journal, 6(1), 1-11. doi:10.2174/1874347101206010001en
uws.contributor.affiliation1Faculty of Engineeringen
uws.contributor.affiliation2Systems Design Engineeringen
uws.typeOfResourceTexten
uws.peerReviewStatusRevieweden
uws.scholarLevelFacultyen


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial 3.0 Unported
Except where otherwise noted, this item's license is described as Attribution-NonCommercial 3.0 Unported

UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages