UWSpace is currently experiencing technical difficulties resulting from its recent migration to a new version of its software. These technical issues are not affecting the submission and browse features of the site. UWaterloo community members may continue submitting items to UWSpace. We apologize for the inconvenience, and are actively working to resolve these technical issues.
 

Row-Column Capacitive Micromachined Ultrasonic Transducers for Medical Imaging

Loading...
Thumbnail Image

Date

2016-12-14

Authors

CHEN, ALBERT I-HSIANG

Journal Title

Journal ISSN

Volume Title

Publisher

University of Waterloo

Abstract

Ultrasound imaging plays an important role in modern medical diagnosis. Recent progress in real-time 3-D ultrasound imaging can offer critical information such as the accurate estimation of organ, cyst, or tumour volumes. However, compared to conventional 2-D ultrasound imaging, the large amount of data and circuit complexity found in 3-D ultrasound imaging results in very expensive systems. Therefore, a simplification scheme for 3-D ultrasound imaging technology is needed for a more wide-spread use and to advance clinical development of volumetric ultrasound. Row-column addressing 2-D array is one particular simplification scheme that requires only N + N addressing lines to activate each element in an N × N array. As a result, the fabrication, circuit, and processing complexity dramatically decrease. Capacitive micromachined ultrasonic transducer (CMUT) technology was chosen to fabricate the array as it offers micro-precision fabrication and a wide bandwidth, which make it an attractive transducer technology. The objective of this thesis is to investigate and demonstrate the imaging potential of row-column CMUT arrays for RT3D imaging. First, the motivation, physics, and modelling of both CMUTs and row-column arrays are described, followed by the demonstration of a customized row-column CMUT pseudo-real-time 3-D imaging system. One particular limitation about row-column arrays discovered as part of this dissertation work is the limited field-of-view of the row-column arrays’ imaging performance. A curved row-column CMUT array was proposed to improve the field-of-view, and the resulting modelling of the acoustic field and simulated reconstructed image are presented. Furthermore, a new fabrication process was proposed to construct a curved row-column CMUT array. The resulting device was tested to demonstrate its flexibility to achieve the necessary curvature. Finally, a new wafer bonding process is introduced to tackle the next generation of RC-CMUT fabrication. Many of the new fabrication techniques reported in this work are useful for CMUT fabrication engineers. The analysis on row-column array also provides additional insights for 2-D array simplification research.

Description

Keywords

mems, cmut, flexible ultrasonic transducer array, row-column addressing ultrasound

LC Keywords

Citation