dc.description.abstractThere is a growing interest in straw bale construction for its low embodied energy and insulation value. Early studies of its structural behaviour and fire resistance have shown it to be a viable alternative to traditional building techniques. However, the biggest remaining obstacle to widespread acceptance is the moisture behaviour within the straw bale walls, especially as it concerns mould growth. The uncertainty of this behaviour leads to the hesitation of building officials and insurance providers to freely accept straw bale construction. Therefore, this study investigates the moisture, temperature and mould growth in straw bale walls, through a combination of analysis, dynamic modeling and field studies. A study of mould is presented along with the current methods available for predicting mould growth. Moisture is the primary controllable factor to mould growth in buildings. Therefore, an understanding of moisture accumulation within straw bale walls is necessary to provide a safe design that precludes mould growth. This study compiles the current state of knowledge of the hygrothermal properties of the materials used in straw bale walls. Then a parametric steady-state analysis is conducted to show the expected behaviour of vapour diffusion and the effects of the material properties. Two 14”thick x 6’ wide x 8’ high straw bale test walls were constructed: one was rendered with a typical cement-lime plaster and the other with a clay plaster. Temperature and moisture were monitored throughout the walls for over a year. These test walls provide more information on the macro behaviour of the walls to both vapour diffusion and, more importantly, rain. Hygrothermal computer modeling was conducted and compared to the test data to assess its accuracy. Thermal modeling was successful, while moisture modeling was found to be more difficult due to a lack of accurate rain data. With better climate data it is expected that accurate hygrothermal modeling of straw bale walls is possible. The result of this work is a general starting point for more detailed studies of the hygrothermal behaviour of straw bale walls with the ultimate goal of assessing the mould risk for various construction techniques and locations.en
dc.language.isoenen
dc.publisherUniversity of Waterlooen
dc.subjectstraw baleen
dc.subjectbuilding scienceen
dc.subjectmoulden
dc.subjecthygrothermalen
dc.subjectfield studyen
dc.titleMoisture Movement and Mould Management in Straw Bale Walls for a Cold Climateen
dc.typeMaster Thesisen
dc.pendingfalseen
dc.subject.programCivil Engineeringen
uws-etd.degree.departmentCivil and Environmental Engineeringen
uws-etd.degreeMaster of Applied Scienceen
uws.typeOfResourceTexten
uws.peerReviewStatusUnrevieweden
uws.scholarLevelGraduateen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record


UWSpace

University of Waterloo Library
200 University Avenue West
Waterloo, Ontario, Canada N2L 3G1
519 888 4883

All items in UWSpace are protected by copyright, with all rights reserved.

DSpace software

Service outages